IN-VITRO ASSESSMENT OF THE BEHAVIOR OF MAGNETIC-RESONANCE ANGIOGRAPHY IN THE PRESENCE OF CONSTRICTIONS

被引:11
作者
SEBOK, NR
SEBOK, DA
WILKERSON, D
MEZRICH, RS
ZATINA, M
机构
[1] PICKER INT,ST DAVIDS,PA
[2] UNIV MED & DENT NEW JERSEY,NEW BRUNSWICK,NJ 08903
关键词
MAGNETIC RESONANCE ANGIOGRAPHY; FLOW; STENOSIS; PHANTOMS; TURBULENCE;
D O I
10.1097/00004424-199307000-00011
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. Time-of-flight magnetic resonance angiography (TOF/MRA) is increasingly used to assess the nature and severity of stenotic blood vessels. Flow artifacts associated with high flows and/or narrow constrictions may confuse the interpretation of these studies. Accurate TOF/MRA evaluations demand an understanding of the nature of these flow effects. METHODS. A two-dimensional TOF pulse sequence was used to acquire images of five smoothly constricted phantoms at various flows. Analysis included assessment of phantom appearance and quantification of apparent constriction diameter and signal variations. RESULTS. Most notable flow phenomena were a cone-shaped region of high signal, a region of signal void, and signal preservation along the wall. When visible, constriction diameter was accurately measured. CONCLUSIONS. The behavior observed in TOF/MRA images can be understood by considering the contributing mechanisms of phase dispersion, turbulence, poststenotic flow eddies, flow reversal, and flow separation.
引用
收藏
页码:604 / 610
页数:7
相关论文
共 11 条
[1]   THE APPEARANCE OF RAPIDLY FLOWING BLOOD ON MAGNETIC-RESONANCE IMAGES [J].
BRADLEY, WG ;
WALUCH, V ;
LAI, KS ;
FERNANDEZ, EJ ;
SPALTER, C .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1984, 143 (06) :1167-1174
[2]  
GOLDWASSER SM, 1984, IEEE COMP GRAPHICS A, V5, P44
[3]  
KELLER P J, 1989, Magnetic Resonance Imaging, V7, P186
[4]   MR ANGIOGRAPHY WITH TWO-DIMENSIONAL ACQUISITION AND 3-DIMENSIONAL DISPLAY - WORK IN PROGRESS [J].
KELLER, PJ ;
DRAYER, BP ;
FRAM, EK ;
WILLIAMS, KD ;
DUMOULIN, CL ;
SOUZA, SP .
RADIOLOGY, 1989, 173 (02) :527-532
[5]  
LITT AW, 1991, AM J NEURORADIOL, V12, P149
[6]   EFFECT OF FLOW-RATE AND VESSEL CALIBER ON CRITICAL ARTERIAL-STENOSIS [J].
MOORE, WS ;
MALONE, JM .
JOURNAL OF SURGICAL RESEARCH, 1979, 26 (01) :1-9
[7]  
SCHULTHESS GK, 1985, RADIOLOGY, V157, P687
[8]   MAGNETIC-RESONANCE-IMAGING AND PULSED DOPPLER SONOGRAPHY OF POSTSTENOTIC JETS - CORRELATION BETWEEN SIGNAL VOID AND FLOW VELOCITY DISTRIBUTION [J].
SPIELMANN, RP ;
ZHEN, J ;
TRIEBEL, HJ ;
NICOLAS, V ;
HELLER, M ;
BUCHELER, E .
MAGNETIC RESONANCE IMAGING, 1992, 10 (06) :893-901
[9]  
SUMNER DS, 1989, VASCULAR SURG, P18
[10]  
VENNARD JK, 1982, ELEMENTARY FLUID MEC, P280