SUITABILITY OF COLLECTION TUBES WITH SEPARATOR GELS FOR THERAPEUTIC DRUG-MONITORING

被引:36
作者
KOCH, TR
PLATOFF, G
机构
[1] Department of Pathology, University of Maryland School of Medicine, Baltimore, MD
关键词
Serum drug monitoring; Specimen collection; Specimen storage;
D O I
10.1097/00007691-199005000-00011
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
The purpose of this study was to determine the suitability of four collection tubes containing separation gels for collection of specimens for 15 therapeutic drugs. To blood tubes from drug-free volunteers, selected drugs were added and measured after centrifugation and storage for 6, 24, and 72 h in the collection tube. We found that the Becton Dickinson SST tube extracted phenytoin even with immediate separation of serum. For prolonged storage, the SST tube was unsuitable for quinidine (>24 h) and lidocaine (>6 h); the Monoject Corvac was unsuitable for lidocaine (any storage). Partially filled tubes caused additional errors. Completely filled Terumo Autosep and Monoject Corvac tubes are satisfactory for all drugs tested if serum is removed promptly. © 1990 Raven Press, Ltd., New York.
引用
收藏
页码:277 / 280
页数:4
相关论文
共 8 条
[1]   STABILITY OF DRUG CONCENTRATIONS IN PLASMA STORED IN SERUM SEPARATOR BLOOD COLLECTION TUBES [J].
BAILEY, DN ;
COFFEE, JJ ;
BRIGGS, JR .
THERAPEUTIC DRUG MONITORING, 1988, 10 (03) :352-354
[2]  
BERGQVIST Y, 1984, CLIN CHEM, V30, P465
[3]  
CHAN KM, 1988, CLIN CHEM, V34, P2158
[4]  
CLAVE LP, 1988, CLIN CHEM, V34, P795
[5]  
FITZSIMMONS WE, 1986, CLIN PHARMACY, V5, P923
[6]   PREPARATION OF SERUM AND PLASMA SAMPLES FOR DETERMINATION OF TRICYCLIC ANTIDEPRESSANTS - EFFECTS OF BLOOD COLLECTION TUBES AND STORAGE [J].
NYBERG, G ;
MARTENSSON, E .
THERAPEUTIC DRUG MONITORING, 1986, 8 (04) :478-482
[7]   EFFECT OF SERUM SEPARATOR BLOOD COLLECTION TUBES ON DRUG CONCENTRATIONS [J].
QUATTROCCHI, F ;
KARNES, HT ;
ROBINSON, JD ;
HENDELES, L .
THERAPEUTIC DRUG MONITORING, 1983, 5 (03) :359-362
[8]   EFFECT OF BLOOD-SAMPLE TUBES ON AMIODARONE AND DESETHYLAMIODARONE CONCENTRATIONS [J].
SIEBERS, RWL ;
CHEN, CT ;
FERGUSON, RI ;
MALING, TJB .
THERAPEUTIC DRUG MONITORING, 1988, 10 (03) :349-351