LOCALIZATION AND NEEDLE ASPIRATION OF BREAST-LESIONS - COMPLICATIONS IN 370 CASES

被引:78
作者
HELVIE, MA
IKEDA, DM
ADLER, DD
机构
[1] Department of Radiology, Univ of MI Medical Center, Ann Arbor, MI 48109-0326
关键词
D O I
10.2214/ajr.157.4.1892023
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A prospective study of the immediate complications of 370 consecutive breast-imaging procedures (203 wire localizations and 167 radiographically or sonographically guided fine-needle aspirations) is reported. Vasovagal reactions occurred in 27 (7%) of 370 cases, ranging in severity from syncope (four of 370, 1%) to mild light-headedness. These vasovagal reactions were independent of procedure type or use of local anesthesia, but were more common in younger patients. Other complications included prolonged (5 min or longer) bleeding (three of 370, 1%) and extreme pain (two of 370, 1%). One patient was found to have malignant hypertension. We conclude that wire localizations and imaging-guided aspirations are generally well tolerated procedures. However, vasovagal reactions are frequent enough to warrant close observation of patients. Radiologists and breast-imaging personnel should be able to recognize and treat vasovagal reactions.
引用
收藏
页码:711 / 714
页数:4
相关论文
共 25 条
[1]   STEREOTACTIC FINE-NEEDLE BIOPSY IN 2594 MAMMOGRAPHICALLY DETECTED NON-PALPABLE LESIONS [J].
AZAVEDO, E ;
SVANE, G ;
AUER, G .
LANCET, 1989, 1 (8646) :1033-1036
[2]   NONPALPABLE BREAST-LESIONS - STEREOTAXIC FINE-NEEDLE ASPIRATION CYTOLOGY [J].
CIATTO, S ;
DELTURCO, MR ;
BRAVETTI, P .
RADIOLOGY, 1989, 173 (01) :57-59
[3]   NONPALPABLE BREAST-TUMORS - DIAGNOSIS WITH STEREOTAXIC LOCALIZATION AND FINE-NEEDLE ASPIRATION [J].
DOWLATSHAHI, K ;
GENT, HJ ;
SCHMIDT, R ;
JOKICH, PM ;
BIBBO, M ;
SPRENGER, E .
RADIOLOGY, 1989, 170 (02) :427-433
[4]   ROLE OF CAPACITANCE AND RESISTANCE VESSELS IN VASOVAGAL SYNCOPE [J].
EPSTEIN, SE ;
STAMPFER, M ;
BEISER, GD .
CIRCULATION, 1968, 37 (04) :524-+
[5]   NEEDLE LOCALIZATION AND FINE-NEEDLE ASPIRATION BIOPSY OF NONPALPABLE BREAST-LESIONS WITH USE OF STANDARD AND STEREOTACTIC EQUIPMENT [J].
EVANS, WP ;
CADE, SH .
RADIOLOGY, 1989, 173 (01) :53-56
[6]  
FEIG SA, 1983, RADIOL CLIN N AM, V21, P155
[7]   BREAST MASSES - US-GUIDED FINE-NEEDLE ASPIRATION BIOPSY [J].
FORNAGE, BD ;
FAROUX, MJ ;
SIMATOS, A .
RADIOLOGY, 1987, 162 (02) :409-414
[8]   PREBIOPSY LOCALIZATION OF NONPALPABLE BREAST-LESIONS [J].
GISVOLD, JJ ;
MARTIN, JK .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1984, 143 (03) :477-481
[9]   HEMODYNAMIC CHANGES DURING SPONTANEOUS VASOVAGAL REACTIONS [J].
GLICK, G ;
YU, PN .
AMERICAN JOURNAL OF MEDICINE, 1963, 34 (01) :42-+
[10]   PREOPERATIVE LOCALIZATION OF NON-PALPABLE BREAST-LESIONS USING A WIRE MARKER AND PERFORATED MAMMOGRAPHIC GRID [J].
GOLDBERG, RP ;
HALL, FM ;
SIMON, M .
RADIOLOGY, 1983, 146 (03) :833-835