INVIVO MEASUREMENT OF PROTON DIFFUSION IN THE PRESENCE OF COHERENT MOTION

被引:28
作者
JOHNSON, GA
MAKI, JH
机构
[1] Department of Radiology, Duke University Medical Center, Durham, NC
关键词
DIFFUSION; MICROSCOPY; MOTION COMPENSATION;
D O I
10.1097/00004424-199106000-00006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Measurement of the self-diffusion coefficient D of water in tissue has been performed traditionally using the technique proposed by Stejskal and Tanner. A variant of that technique is shown here, employing flow-compensated gradients that significantly reduce the sensitivity to small coherent motions that are common in body imaging. An interleaved sequence with four values of diffusion-sensitizing gradient (b) minimizes registration errors. Eddy currents and other systematic errors are reduced, permitting the measurement of standards in an imaging context within 5% of nonimaging values in the literature. The flow-compensated sequence permits the measure of D for tissues in the abdominal cavity of the rat. We present in vivo measurements of D for the following rat tissues: liver, kidney (cortex), kidney (medulla) muscle, brain, fat.
引用
收藏
页码:540 / 545
页数:6
相关论文
共 23 条
[1]   AN IMPROVED NUCLEAR-MAGNETIC-RESONANCE DIFFUSION-COEFFICIENT IMAGING METHOD USING AN OPTIMIZED PULSE SEQUENCE [J].
AHN, CB ;
LEE, SY ;
NALCIOGLU, O ;
CHO, ZH .
MEDICAL PHYSICS, 1986, 13 (06) :789-793
[2]   DIFFUSION-LIMITED RESOLUTION IN NUCLEAR MAGNETIC-RESONANCE MICROSCOPY [J].
CALLAGHAN, PT ;
ECCLES, CD .
JOURNAL OF MAGNETIC RESONANCE, 1988, 78 (01) :1-8
[3]   NUCLEAR MAGNETIC-RESONANCE MICROSCOPY WITH 4-MU-M RESOLUTION - THEORETICAL-STUDY AND EXPERIMENTAL RESULTS [J].
CHO, ZH ;
AHN, CB ;
JUH, SC ;
LEE, HK ;
JACOBS, RE ;
LEE, S ;
YI, JH ;
JO, JM .
MEDICAL PHYSICS, 1988, 15 (06) :815-824
[4]   RESTRICTED DIFFUSION IN BIOPHYSICAL SYSTEMS - EXPERIMENT [J].
COOPER, RL ;
CHANG, DB ;
YOUNG, AC ;
MARTIN, CJ ;
ANCKERJO.B .
BIOPHYSICAL JOURNAL, 1974, 14 (03) :161-177
[5]   MAGNETIC-RESONANCE MICROSCOPY OF THE RAT THORAX AND ABDOMEN [J].
HEDLUND, LW ;
JOHNSON, GA ;
MILLS, GI .
INVESTIGATIVE RADIOLOGY, 1986, 21 (11) :843-846
[6]   NMR PULSED GRADIENT DIFFUSION MEASUREMENTS .2. RESIDUAL GRADIENTS AND LINESHAPE DISTORTIONS [J].
HROVAT, MI ;
WADE, CG .
JOURNAL OF MAGNETIC RESONANCE, 1981, 45 (01) :67-80
[7]   CIRCULATION OF WATER WITHIN WHEAT-GRAIN REVEALED BY NUCLEAR MAGNETIC-RESONANCE MICRO-IMAGING [J].
JENNER, CF ;
XIA, Y ;
ECCLES, CD ;
CALLAGHAN, PT .
NATURE, 1988, 336 (6197) :399-402
[8]   MR IMAGING OF INTRAVOXEL INCOHERENT MOTIONS - APPLICATION TO DIFFUSION AND PERFUSION IN NEUROLOGIC DISORDERS [J].
LEBIHAN, D ;
BRETON, E ;
LALLEMAND, D ;
GRENIER, P ;
CABANIS, E ;
LAVALJEANTET, M .
RADIOLOGY, 1986, 161 (02) :401-407
[9]   TEMPERATURE MAPPING WITH MR IMAGING OF MOLECULAR-DIFFUSION - APPLICATION TO HYPERTHERMIA [J].
LEBIHAN, D ;
DELANNOY, J ;
LEVIN, RL .
RADIOLOGY, 1989, 171 (03) :853-857
[10]  
LEBIHAN D, 1988, RADIOLOGY, V168, P479