EXERCISE MYOCARDIAL PERFUSION SCINTIGRAPHY WITH TECHNETIUM-99M METHOXY ISOBUTYLISONITRILE - A COMPARATIVE-STUDY WITH TL-201

被引:28
作者
NAJM, YC
MAISEY, MN
CLARKE, SM
FOGELMAN, I
CURRY, PVL
SOWTON, E
机构
[1] GUYS & ST THOMAS HOSP,UNITED MED & DENT SCH,DIV RADIOL SCI,LONDON SE1 9RT,ENGLAND
[2] GUYS & ST THOMAS HOSP,DEPT CARDIOL,LONDON SE1 9RT,ENGLAND
[3] GUYS & ST THOMAS HOSP,DEPT NUCL MED,LONDON SE1 9RT,ENGLAND
关键词
Isobutylisonitrile; Perfusion scintigraphy; Technetium-99m; Thallium-201;
D O I
10.1016/0167-5273(90)90252-Z
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The evaluation of technetium-99m methoxy isobutylisonitrile for the diagnosis of coronary artery disease requires comparative validation against thallium-201, the established perfusion imaging agent. We have compared myocardial and lung uptake of both radiotracers following maximal exercise in 52 patients: 40 with angiographically proven coronary disease. Qualitative and quantitative image analysis showed the diagnostic sensitivity of technetium-99m methoxy isobutylisonitrile to compare favourably with that of thallium-201 as reflected by the mean number of ischaemic segments identified: 5.6 ± 2.5 vs 4.8 ± 2.1 by qualitative analysis, and 5.7 ± 3.2 vs 5.0 ± 2.6 segments by quantitative analysis. More reversibly ischaemic segments per patient were identified with technetium-99m methoxy isobutylisonitrile than with thallium-201: 3.6 ± 2.3 vs 1.8 ± 1.9. There was a higher exercise myocardial to background count ratio with technetium-99m methoxy isobutylisonitrile: 3.16:1 vs 2.58:1, and the mean exercise lung uptake normalised to left ventricular uptake ('lung index'), was lower for technetium-99m methoxy isobutylisonitrile than for thallium-201 (36 ± 8% vs 40 ± 10%). Five of the six patients with abnormal elevation of the thallium-201 exercise lung index also had elevation of the technetium-99m methoxy isobutylisonitrile exercise lung index, and all had extensive coronary artery disease. These results indicate that technetium-99m methoxy isobutylisonitrile is at least as effective as thallium-201 for detecting exercise induced myocardial ischaemia. However, technetium-99m methoxy isobutylisonitrile provides a better image quality and may be a more sensitive marker of defect reversibility. For both radiotracers lung uptake is increased with extensive coronary artery disease and measurement of this variable provides prognostic information. © 1990.
引用
收藏
页码:93 / 102
页数:10
相关论文
共 14 条
  • [1] QUANTIFICATION OF PULMONARY TL-201 ACTIVITY AFTER UPRIGHT EXERCISE IN NORMAL PERSONS - IMPORTANCE OF PEAK HEART-RATE AND PROPRANOLOL USAGE IN DEFINING NORMAL VALUES
    BROWN, KA
    BOUCHER, CA
    OKADA, RD
    STRAUSS, HW
    POHOST, GM
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1984, 53 (11) : 1678 - 1682
  • [2] ENHANCED DETECTION OF PROXIMAL RIGHT CORONARY-ARTERY STENOSIS WITH THE ADDITIONAL ANALYSIS OF RIGHT VENTRICULAR TL-201 UPTAKE IN STRESS SCINTIGRAMS
    GUTMAN, J
    BRACHMAN, M
    ROZANSKI, A
    MADDAHI, J
    WAXMAN, A
    BERMAN, DS
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1983, 51 (08) : 1256 - 1260
  • [3] HOLMAN BL, 1987, J NUCL MED, V28, P13
  • [4] HOMMA S, 1987, J NUCL MED, V28, P1531
  • [5] TL-201 MYOCARDIAL SCINTIGRAPHY
    ISKANDRIAN, AS
    HAKKI, AH
    [J]. AMERICAN HEART JOURNAL, 1985, 109 (01) : 113 - 129
  • [6] KARCHER G, 1987, Journal of Nuclear Medicine, V28, P654
  • [7] MADDAHI J, 1987, Journal of Nuclear Medicine, V28, P654
  • [8] MOUSA S A, 1987, Journal of Nuclear Medicine, V28, P619
  • [9] NAJM YC, 1987, NUCL MED COMMUN, V8, P235
  • [10] NAJM YC, 1989, IN PRESS BR HEART J, V61