STUDIES ON THE EFFECTS OF IMIDAZOLE ON THE PEROXYOXALATE CHEMILUMINESCENCE DETECTION SYSTEM FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY

被引:32
作者
IMAI, K [1 ]
NISHITANI, A [1 ]
TSUKAMOTO, Y [1 ]
WANG, WH [1 ]
KANDA, S [1 ]
HAYAKAWA, K [1 ]
MIYAZAKI, M [1 ]
机构
[1] KANAZAWA UNIV,FAC PHARMACEUT SCI,KANAZAWA,ISHIKAWA 920,JAPAN
关键词
D O I
10.1002/bmc.1130040305
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The catalytic effect of bases (imidazole, pyridine, Tris and triethylamine) on the peroxyoxalate chemiluminescence (PO‐CL) reaction for high performance liquid chromatography (HPLC) was investigated. Imidazole increased PO‐CL intensity extraordinarily, whereas the other bases (pyridine, Tris and triethylamine) did not. The peak heights of dipyridamole (coronary vasodilator) obtained using the eluents containing buffers were largest at pH 7.0, a few times less at pH 6.0 and pH 5.0, 100 times less at pH 4.0 and a few hundred times less at pH 3.0. The eluents containing buffers at pH 3, 4, 5, 6 or 7 each with imidazole increased the peak heights by a few to ten times as compared with those without imidazole, and those peak heights were within one order of magnitude. On the other hand, the eluent containing buffer at pH 2 did not affect the peak heights with or without imidazole. Bis(4‐nitro‐2‐(3,6,9‐trioxadecyloxycarbonyl)phenyl) oxalate (TDPO) alone and bis(2,4‐dinitrophenyl)oxalate (DNPO) plus TDPO were recommended to be used against eluents containing buffers of pH 5 – 7 and pH 3 – 4, respectively. Dipyridamole and benzydamine hydrochloride (anti‐inflamatory drug) were separated on the ODS column and detected by the present system. The detection limits of dipyridamole and benzydamine hydrochloride were 40 amol and 270 fmol, respectively. Copyright © 1990 John Wiley & Sons, Ltd.
引用
收藏
页码:100 / 104
页数:5
相关论文
共 42 条
  • [1] OPTIMIZATION OF A PEROXYOXALATE CHEMI-LUMINESCENCE DETECTION SYSTEM FOR THE LIQUID-CHROMATOGRAPHIC DETERMINATION OF FLUORESCENT COMPOUNDS
    DEJONG, GJ
    LAMMERS, N
    SPRUIT, FJ
    BRINKMAN, UAT
    FREI, RW
    [J]. CHROMATOGRAPHIA, 1984, 18 (03) : 129 - 133
  • [2] ANALYTICAL IMPLICATIONS OF THE HALF-LIFE OF THE CHEMILUMINESCENCE SIGNAL IN THE PEROXYOXALATE DETECTION SYSTEM FOR LIQUID-CHROMATOGRAPHY
    DEJONG, GJ
    LAMMERS, N
    SPRUIT, FJ
    FREI, RW
    BRINKMAN, UAT
    [J]. JOURNAL OF CHROMATOGRAPHY, 1986, 353 : 249 - 257
  • [3] INVESTIGATION OF INSTRUMENT PARAMETERS FOR THE APPLICATION OF PEROXYOXALATE CHEMI-LUMINESCENCE DETECTION TO MICROBORE CHROMATOGRAPHY
    GRAYESKI, ML
    WEBER, AJ
    [J]. ANALYTICAL LETTERS PART A-CHEMICAL ANALYSIS, 1984, 17 (13): : 1539 - 1552
  • [4] COUMARIN DERIVATIZING AGENTS FOR CARBOXYLIC-ACID DETECTION USING PEROXYOXALATE CHEMILUMINESCENCE WITH LIQUID-CHROMATOGRAPHY
    GRAYESKI, ML
    DEVASTO, JK
    [J]. ANALYTICAL CHEMISTRY, 1987, 59 (08) : 1203 - 1206
  • [5] STOPPED-FLOW DETERMINATION OF THE PARAMETERS AFFECTING THE APPLICATION OF PEROXYOXALATE CHEMI-LUMINESCENCE TO HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETECTION
    HANAOKA, N
    GIVENS, RS
    SCHOWEN, RL
    KUWANA, T
    [J]. ANALYTICAL CHEMISTRY, 1988, 60 (20) : 2193 - 2197
  • [6] HANAOKA N, 1989, ANAL CHEM, V61, P1300
  • [7] HAYAKAWA K, 1989, J CHROMATOGR, V464, P343
  • [8] EVALUATION OF FLUORESCENT COMPOUNDS FOR PEROXYOXALATE CHEMILUMINESCENCE DETECTION
    HONDA, K
    MIYAGUCHI, K
    IMAI, K
    [J]. ANALYTICA CHIMICA ACTA, 1985, 177 : 111 - 120
  • [9] EVALUATION OF ARYL OXALATES FOR CHEMILUMINESCENCE DETECTION IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    HONDA, K
    MIYAGUCHI, K
    IMAI, K
    [J]. ANALYTICA CHIMICA ACTA, 1985, 177 : 103 - 110
  • [10] BIS(2,4-DINITROPHENYL) OXALATE AS A CHEMI-LUMINESCENCE REAGENT IN DETERMINATION OF FLUORESCENT COMPOUNDS BY FLOW-INJECTION ANALYSIS
    HONDA, K
    SEKINO, J
    IMAI, K
    [J]. ANALYTICAL CHEMISTRY, 1983, 55 (06) : 940 - 943