CHARACTERIZATION OF ACTIVATED-SLUDGE AND CONDITIONING WITH CATIONIC POLYELECTROLYTES

被引:68
作者
ERIKSSON, L
ALM, B
机构
关键词
FILTRATION RESISTANCE; FLOC STRENGTH; FLOC STRUCTURE; EXTRACELLULAR POLYMERS; RESIDUAL TURBIDITY; POLYELECTROLYTES;
D O I
10.2166/wst.1993.0048
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Three cationic polyelectrolytes with different charge densities were used to condition activated sludge samples from a municipal plant during a period when the sludge characteristics changed strongly. Initially the sludge had high residual turbidity after sedimentation, high filtration resistance, low floc strength and high amounts of extractable extracellular polymers (ECP). These problems could be related to the snow melting that was going on. When that ceased the sludge recovered as shown by decreased residual turbidity, filtration resistance and amount of extractable ECP and increased floc strength. The polyelectrolytes with 40 and 100 % charge density gave good and similar filterabilities during the whole investigation period. With the 10 % charged polymer the filtration resistance was generally higher and especially so during the snow melting period. The reason is that low charge density polymers flocculate with a bridging mechanism. This gives a flexible floc structure which allows the formation of dense filter cakes and also to some extent preserves the original structure. High charge density polymers give closer contacts between the particles and thus a more inflexible and open structure which is favourable in filtration.
引用
收藏
页码:203 / 212
页数:10
相关论文
共 22 条
[1]  
BOWEN PT, 1982, THESIS CLEMSON U CLE
[2]  
BRADFORD MM, 1976, ANAL BIOCHEM, V72, P248, DOI 10.1016/0003-2697(76)90527-3
[3]   FLOCCULATION AND ADSORPTION PROPERTIES OF CATIONIC POLYELECTROLYTES TOWARD NA-MONTMORILLONITE DILUTE SUSPENSIONS [J].
DURANDPIANA, G ;
LAFUMA, F ;
AUDEBERT, R .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1987, 119 (02) :474-480
[4]   CONDITIONING OF BIOLOGICAL SLUDGES WITH CATIONIC POLYELECTROLYTES [J].
ERIKSSON, L .
WATER SCIENCE AND TECHNOLOGY, 1987, 19 (5-6) :859-868
[5]   SETTLING PROPERTIES OF ACTIVATED-SLUDGE RELATED TO FLOC STRUCTURE [J].
ERIKSSON, L ;
HARDIN, AM .
WATER SCIENCE AND TECHNOLOGY, 1984, 16 (10-1) :55-68
[6]   EVALUATION OF SLUDGE PROPERTIES AT AN ACTIVATED-SLUDGE PLANT [J].
ERIKSSON, L ;
STEEN, I ;
TENDAJ, M .
WATER SCIENCE AND TECHNOLOGY, 1992, 25 (06) :251-265
[7]  
ERIKSSON L, 1992, CHEM WATER WASTEWATE, V2, P19
[8]  
ERIKSSON L, 1989, FLOCCULATION DEWATER, P179
[9]  
ERIKSSON L, IN PRESS COLLOIDS SU
[10]  
Eriksson L.B., 1987, FLOCCULATION BIOTECH, P441