VISUAL-DISPLAY FORMAT AFFECTS THE ABILITY OF ANESTHESIOLOGISTS TO DETECT ACUTE PHYSIOLOGICAL - A LABORATORY STUDY EMPLOYING A CLINICAL DISPLAY SIMULATOR

被引:34
作者
GURUSHANTHAIAH, K
WEINGER, MB
ENGLUND, CE
机构
[1] VET AFFAIRS MED CTR,ANESTHESIA SERV,SAN DIEGO,CA 92161
[2] USN,CTR COMMAND CONTROL & OCEAN SURVEILLANCE,DIV RES DEV TEST & EVALUAT NRAD,SAN DIEGO,CA 92152
[3] UNIV CALIF SAN DIEGO,SAN DIEGO,CA 92103
关键词
Computers: simulation; Equipment: monitors; Human performance: human factors; Visual displays: graphic;
D O I
10.1097/00000542-199512000-00009
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Anesthesiologists use data presented on visual displays to monitor patients' physiologic status. Although studies in nonmedical fields have suggested differential effects on performance among display formats, few studies have examined the effect of display format on anesthesiologist monitoring performance. Methods: A computer-based clinical display simulator was developed to evaluate the efficacy of three currently used display formats (numeric, histogram, or polygon displays) in a partial-task laboratory simulation. The subjects' task consisted solely of detecting any changes in the values of the physiologic variables depicted on a simulated clinical display. Response latency and accuracy were used as measures of performance. Results: Thirteen anesthesia residents and five nonmedical volunteers, were enrolled as subjects. Use of either the histogram or polygon displays significantly improved response latencies and allowed greater accuracy compared with the numeric display in the anesthesia residents. Neither response latency nor accuracy improved with additional exposure to these displays. In contrast, display format did not significantly affect response latency or accuracy in the nonmedical volunteers. Conclusions: The results of this study suggest that graphic displays may enhance the detection of acute changes in patient physiologic status during anesthesia administration. This research also demonstrates the importance of assessing performance on clinical devices by studying actual users rather than random subjects. Further research is required to elucidate the display elements and characteristics that best support different aspects of the anesthesiologist's monitoring tasks.
引用
收藏
页码:1184 / 1193
页数:10
相关论文
共 19 条
[1]  
[Anonymous], 1971, STAT PRINCIPLES EXPT
[2]   EMERGENT FEATURES AND GRAPHICAL ELEMENTS - DESIGNING MORE EFFECTIVE CONFIGURAL DISPLAYS [J].
BENNETT, KB ;
TOMS, ML ;
WOODS, DD .
HUMAN FACTORS, 1993, 35 (01) :71-97
[3]  
BENNETT KB, 1992, HUM FACTORS, V35, P513
[4]   INFORMATION INTEGRATION AND THE OBJECT DISPLAY - AN INTERACTION OF TASK DEMANDS AND DISPLAY SUPERIORITY [J].
CARSWELL, CM ;
WICKENS, CD .
ERGONOMICS, 1987, 30 (03) :511-527
[5]   ALPHANUMERIC AND GRAPHIC DISPLAYS FOR DYNAMIC PROCESS MONITORING AND CONTROL [J].
COURY, BG ;
PIETRAS, CM .
ERGONOMICS, 1989, 32 (11) :1373-1389
[6]   TIME STRESS AND THE PROCESSING OF VISUAL-DISPLAYS [J].
COURY, BG ;
BOULETTE, MD .
HUMAN FACTORS, 1992, 34 (06) :707-725
[7]   EFFECT OF UNCERTAINTY AND DIAGNOSTICITY ON CLASSIFICATION OF MULTIDIMENSIONAL DATA WITH INTEGRAL AND SEPARABLE DISPLAYS OF SYSTEM STATUS [J].
COURY, BG ;
BOULETTE, MD ;
SMITH, RA .
HUMAN FACTORS, 1989, 31 (05) :551-569
[8]   EFFECTS OF EVENT RATE AND SIGNAL DIFFICULTY ON OBSERVING RESPONSES AND DETECTION MEASURES IN VIGILANCE [J].
GURALNICK, MJ .
JOURNAL OF EXPERIMENTAL PSYCHOLOGY, 1973, 99 (02) :261-265
[9]   HUMAN VIGILANCE [J].
HOLLAND, JG .
SCIENCE, 1958, 128 (3315) :61-67
[10]   HOLISTIC PERIPHERAL PROCESSING OF A POLYGON DISPLAY [J].
HUGHES, T ;
MACRAE, AW .
HUMAN FACTORS, 1994, 36 (04) :645-651