PRESSURE AND MODIFIER PROGRAMMING IN PACKED-COLUMN SUPERCRITICAL FLUID CHROMATOGRAPHY

被引:8
作者
MORRISSEY, MA [1 ]
GIORGETTI, A [1 ]
POLASEK, M [1 ]
PERICLES, N [1 ]
WIDMER, HM [1 ]
机构
[1] CIBA GEIGY AG,CENT ANALYT RES,ANALYT RES,CH-4002 BASEL,SWITZERLAND
关键词
D O I
10.1093/chromsci/29.6.237
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Using a self-adjusting, microprocessor-controlled valve and computer-controlled piston pumps, modifier and pressure gradients may be generated separately or simultaneously to improve separation. For several test compounds, the reproducibility of retention time and peak area is found to be less than 2% relative standard deviation when pressure and modifier concentration are programmed together. Examples are shown for samples of polystyrenes and epoxy resins where programming both composition and pressure yields a separation which is superior to programming only one or the other.
引用
收藏
页码:237 / 242
页数:6
相关论文
共 14 条
[1]   MODIFIER EFFECTS ON RETENTION AND PEAK SHAPE IN SUPERCRITICAL FLUID CHROMATOGRAPHY [J].
BLILIE, AL ;
GREIBROKK, T .
ANALYTICAL CHEMISTRY, 1985, 57 (12) :2239-2242
[2]   NILE RED AS A SOLVATOCHROMIC DYE FOR MEASURING SOLVENT STRENGTH IN NORMAL LIQUIDS AND MIXTURES OF NORMAL LIQUIDS WITH SUPERCRITICAL AND NEAR CRITICAL FLUIDS [J].
DEYE, JF ;
BERGER, TA ;
ANDERSON, AG .
ANALYTICAL CHEMISTRY, 1990, 62 (06) :615-622
[3]   SUPERCRITICAL FLUID CHROMATOGRAPHY [J].
GERE, DR .
SCIENCE, 1983, 222 (4621) :253-259
[4]   HIGH PRESSURE GAS CHROMATOGRAPHY OF NONVOLATILE SPECIES [J].
GIDDINGS, JC ;
MYERS, MN ;
MCLAREN, L ;
KELLER, RA .
SCIENCE, 1968, 162 (3849) :67-&
[5]   MIXED MOBILE PHASES AND PRESSURE PROGRAMMING IN PACKED AND CAPILLARY COLUMN SUPERCRITICAL FLUID CHROMATOGRAPHY - A UNIFIED APPROACH [J].
GIORGETTI, A ;
PERICLES, N ;
WIDMER, HM ;
ANTON, K ;
DATWYLER, P .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1989, 27 (06) :318-324
[6]   LIQUID AND SUPERCRITICAL CARBON-DIOXIDE AS ORGANIC-SOLVENTS [J].
HYATT, JA .
JOURNAL OF ORGANIC CHEMISTRY, 1984, 49 (26) :5097-5101
[7]   PROGRAMMING OF PRESSURE AND MOBILE PHASE-COMPOSITION AT CONSTANT FLOW-RATE USING A SELF-ADJUSTING VALVE IN SUPER-CRITICAL-FLUID CHROMATOGRAPHY [J].
KUPPERS, S ;
LORENSCHAT, B ;
SCHMITZ, FP ;
KLESPER, E .
JOURNAL OF CHROMATOGRAPHY, 1989, 475 :85-94
[8]   ANALYSIS OF VARIOUS CLASSES OF DRUGS - BY CAPILLARY SUPERCRITICAL FLUID CHROMATOGRAPHY [J].
LATER, DW ;
RICHTER, BE ;
KNOWLES, DE ;
ANDERSEN, MR .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1986, 24 (06) :249-253
[9]   SYNCHRONIZED TEMPERATURE DENSITY PROGRAMMING IN CAPILLARY SUPERCRITICAL FLUID CHROMATOGRAPHY [J].
LATER, DW ;
CAMPBELL, ER ;
RICHTER, BE .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1988, 11 (01) :65-69
[10]  
Novotny M., 1981, ANAL CHEM, V53, P407