BIOMATERIAL-INDUCED ALTERATIONS OF NEUTROPHIL SUPEROXIDE PRODUCTION

被引:52
作者
KAPLAN, SS
BASFORD, RE
MORA, E
JEONG, MH
SIMMONS, RL
机构
[1] UNIV PITTSBURGH,SCH MED,DEPT MOLEC GENET & BIOCHEM,PITTSBURGH,PA 15213
[2] UNIV PITTSBURGH,SCH MED,DEPT SURG,PITTSBURGH,PA 15213
来源
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH | 1992年 / 26卷 / 08期
关键词
D O I
10.1002/jbm.820260806
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Because periprosthetic infection remains a vexing problem for patients receiving implanted devices, we evaluated the effect of several materials on neutrophil free radical production. Human peripheral blood neutrophils were incubated with several sterile, lipopolysaccharide (LPS)-free biomaterials used in surgically implantable prosthetic devices: polyurethane, woven dacron, and velcro. Free radical formation as the superoxide (O2-) anion was evaluated by cytochrome c reduction in neutrophils that were exposed to the materials and then removed and in neutrophils allowed to remain in association with the materials. Neutrophils exposed to polyurethane or woven dacron for 30 or 60 min and then removed consistently exhibited an enhanced release of O2- after simulation via receptor engagement with formyl methionyl-leucyl-phenylalanine. Enhanced reactivity to stimulation via protein kinase C with phorbol myristate acetate, however, was not consistently observed. The cells evaluated for O2- release during continous association with the biomaterials showed enhanced metabolic activity during short periods of association (especially with polyurethane and woven dacron). Although O2- release by neutrophils in association with these materials decreased with longer periods of incubation, it was not obliterated. These studies, therefore, show that several commonly used biomaterials activate neutrophils soon after exposure and that this activated state diminishes with prolonged exposure but nevertheless remains measurable. The diminishing level of activity with prolonged exposure, however, suggests that ultimately a depletion of reactivity may occur and may result in increased susceptibility to periprosthetic infection.
引用
收藏
页码:1039 / 1051
页数:13
相关论文
共 28 条
[1]  
ALMGREN B, 1985, ACTA CHIR SCAND S, V529, P91
[2]   INFECTION OF VASCULAR PROSTHESES CAUSED BY BACTERIAL BIOFILMS [J].
BERGAMINI, TM ;
BANDYK, DF ;
GOVOSTIS, D ;
KAEBNICK, HW ;
TOWNE, JB .
JOURNAL OF VASCULAR SURGERY, 1988, 7 (01) :21-30
[3]  
BERNHARD VM, 1975, SURG CLIN N AM, V55, P1412
[4]  
BOYUM A, 1968, SCAND J CLIN LAB S97, V21, P1
[5]  
Charnley J, 1972, Clin Orthop Relat Res, V87, P167, DOI 10.1097/00003086-197209000-00020
[6]  
DISABATO G, 1986, METHOD ENZYMOL, V132, P407
[7]  
Dougherty S H, 1989, Infect Dis Clin North Am, V3, P199
[8]  
DOUGHERTY SH, 1982, CURR PROB SURG, V19, P221
[9]   BIOMATERIAL-CENTERED INFECTION - MICROBIAL ADHESION VERSUS TISSUE INTEGRATION [J].
GRISTINA, AG .
SCIENCE, 1987, 237 (4822) :1588-1595
[10]   BIOMATERIAL-CENTERED SEPSIS AND THE TOTAL ARTIFICIAL-HEART - MICROBIAL ADHESION VS TISSUE INTEGRATION [J].
GRISTINA, AG ;
DOBBINS, JJ ;
GIAMMARA, B ;
LEWIS, JC ;
DEVRIES, WC .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1988, 259 (06) :870-874