INDIVIDUAL RELIABILITY OF AMPLITUDE DISTRIBUTION IN TOPOGRAPHICAL MAPPING OF EEG

被引:62
作者
BURGESS, A
GRUZELIER, J
机构
[1] Department of Psychiatry, Charing Cross and Westminiter Medical School, Hammersmith
来源
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY | 1993年 / 86卷 / 04期
关键词
EEG RELIABILITY; EEG TOPOGRAPHY;
D O I
10.1016/0013-4694(93)90101-Z
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Whilst there is an accumulation of evidence suggesting that many quantitative EEG parameters show good stability and reliability, no previous study has considered whether the spatial distribution of EEG amplitude is reliable over time within a session. This study reports on the spatio-temporal reliability of EEG using data recorded from 24 subjects in a baseline condition with eyes open and also whilst performing a simple motor task. Both the internal stability and test-retest reliability for electrode parameters were comparable to previously published data. For most individuals, amplitude distribution was stable within each recording condition. but the test-retest reliability after 40 min was less good with the poorest reliability in the delta frequency band. Most subjects showed spatio-temporal reliability of less than 0.7 in at least one frequency band. In contrast, spatio-temporal reliability for the group average was good and exceeded 0.88 in all frequency bands. It is argued that the results indicate that reliability is insufficient to allow topographical comparisons for a single individual, but is more than adequate to allow group comparisons.
引用
收藏
页码:219 / 223
页数:5
相关论文
共 7 条
[1]   TEST-RETEST RELIABILITY OF SPECTRAL PARAMETERS OF THE EEG [J].
GASSER, T ;
BACHER, P ;
STEINBERG, H .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1985, 60 (04) :312-319
[2]   NEUROMETRIC EVALUATION OF COGNITIVE DYSFUNCTIONS AND NEUROLOGICAL DISORDERS IN CHILDREN [J].
JOHN, ER ;
PRICHEP, L ;
AHN, H ;
EASTON, P ;
FRIDMAN, J ;
KAYE, H .
PROGRESS IN NEUROBIOLOGY, 1983, 21 (04) :239-290
[3]  
Luria Aleksandr Romanovich, 2012, HIGHER CORTICAL FUNC
[4]   SHORT-TERM VARIABILITY IN EEG FREQUENCY-ANALYSIS [J].
OKEN, BS ;
CHIAPPA, KH .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1988, 69 (03) :191-198
[5]   RELIABILITY OF TOPOGRAPHIC QUANTITATIVE EEG AMPLITUDE IN HEALTHY LATE-MIDDLE-AGED AND ELDERLY SUBJECTS [J].
POLLOCK, VE ;
SCHNEIDER, LS ;
LYNESS, SA .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1991, 79 (01) :20-26
[6]   TEST-RETEST RELIABILITY IN EEG FREQUENCY-ANALYSIS [J].
SALINSKY, MC ;
OKEN, BS ;
MOREHEAD, L .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1991, 79 (05) :382-392
[7]  
STREINER DL, 2003, HLTH MEASUREMENT SCA