SENSITIVITY AND SELECTIVITY OF THE ELECTROCHEMICAL DETECTION OF THE COPPER(II) COMPLEXES OF BIOACTIVE PEPTIDES, AND COMPARISON TO MODEL STUDIES BY ROTATING RING-DISC ELECTRODE

被引:25
作者
CHEN, JG [1 ]
WOLTMAN, SJ [1 ]
WEBER, SG [1 ]
机构
[1] UNIV PITTSBURGH,DEPT CHEM,PITTSBURGH,PA 15260
关键词
D O I
10.1016/0021-9673(94)00843-X
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Post-column reaction of peptides with Cu(II) can be used for the electrochemical detection of peptides as their biuret complexes. Understanding of the behavior (sensitivity at the anode and cathode in the dual-series erectrochemical detector) of the system is facilitated through the observation of the rotating ring disc voltammetry of some model compounds. In operation, the anodic signal from the oxidation of the Cu(II)-peptide to the Cu(III) form can be used to detect peptides, or the downstream cathode can be used to detect the Cu(III) form. The signals appear at about 0.4 V (anode) for tetra- and longer peptides, 0.65 V for tripeptides. The anode signal is augmented by tyrosine (oxidation at 0.4-0.5 V) and tryptophan (0.5-0.6 V). If the cathode is used as the detector in a two working electrode cell, the sensitivity depends on the stability of the Cu(III) product. This is peptide dependent, but the signal is significant and useful analytically. Twenty-three bioactive peptides in two groups, naturally electrochemically active and naturally electrochemically silent, and several model compounds have been studied. Both naturally electrochemically active peptides (contain tyrosine and/or tryptophan) and naturally electrochemically silent peptides have been studied. Chromatography with an acetonitrile gradient has been used to separate the peptides in each group. Detection limits are for non-electroactive peptides in the range of 16-100 fmol (10- mu l injection 1.6-10 nM, 100 mu l injection 0.16-1.0 nM), and for electroactive peptides in the range of 6-40 fmol (0.6-4.0 nM for a 10- mu l injection and 60-400 pM for a 100- mu l injection). A tryptic digest of bovine cytochrome c is easily seen at 100 nM.
引用
收藏
页码:301 / 315
页数:15
相关论文
共 23 条
[1]  
ALBERY WJ, 1971, RING DISC ELECTRODES, P17
[2]   LIGAND EFFECTS ON THERMODYNAMIC STABILIZATION OF COPPER(III)-PEPTIDE COMPLEXES [J].
BOSSU, FP ;
CHELLAPPA, KL ;
MARGERUM, DW .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1977, 99 (07) :2195-2203
[3]   NEW DERIVATIZING AGENTS FOR AMINO-ACIDS AND PEPTIDES .1. FACILE SYNTHESIS OF N-SUBSTITUTED 1-CYANOBENZ[F]ISOINDOLES AND THEIR SPECTROSCOPIC PROPERTIES [J].
CARLSON, RG ;
SRINIVASACHAR, K ;
GIVENS, RS ;
MATUSZEWSKI, BK .
JOURNAL OF ORGANIC CHEMISTRY, 1986, 51 (21) :3978-3983
[4]   DESIGN AND SYNTHESIS OF NOVEL CYCLIC RGD-CONTAINING PEPTIDES AS HIGHLY POTENT AND SELECTIVE INTEGRIN ALPHA(IIB)BETA(3) ANTAGONISTS [J].
CHENG, S ;
CRAIG, WS ;
MULLEN, D ;
TSCHOPP, JF ;
DIXON, D ;
PIERSCHBACHER, MD .
JOURNAL OF MEDICINAL CHEMISTRY, 1994, 37 (01) :1-8
[5]   PULSE RADIOLYTIC MEASUREMENT OF REDOX POTENTIALS - THE TYROSINE AND TRYPTOPHAN RADICALS [J].
DEFELIPPIS, MR ;
MURTHY, CP ;
FARAGGI, M ;
KLAPPER, MH .
BIOCHEMISTRY, 1989, 28 (11) :4847-4853
[6]  
DOU L, 1990, Biochromatography, V5, P74
[7]   SIMULTANEOUS ANALYSIS OF METHIONINE-ENKEPHALIN AND LEUCINE-ENKEPHALIN FROM RAT-BRAIN - QUANTIFICATION BY LIQUID-CHROMATOGRAPHY - ELECTROCHEMISTRY [J].
FLEMING, LH ;
REYNOLDS, NC .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 431 (01) :65-76
[8]  
HANCOCK WS, 1984, HDB HPLC SEPARATION, V2, P3
[9]   NEUROPEPTIDES IN PERSPECTIVE - THE LAST 10 YEARS [J].
HOKFELT, T .
NEURON, 1991, 7 (06) :867-879
[10]   OPIOID AND TACHYKININ PEPTIDES, AND THEIR PRECURSORS AND PRECURSOR-PROCESSING ENZYMES, IN HUMAN CEREBROSPINAL-FLUID [J].
LIU, DX ;
DASS, C ;
WOOD, G ;
DESIDERIO, DM .
JOURNAL OF CHROMATOGRAPHY, 1990, 500 :395-412