THE ASSESSMENT OF CAROTID AND VERTEBRAL ARTERIES - A COMPARISON OF CFM DUPLEX ULTRASOUND WITH INTRAVENOUS DIGITAL SUBTRACTION ANGIOGRAPHY

被引:12
作者
COLQUHOUN, I
OATES, CP
MARTIN, K
HALL, K
WHITTINGHAM, TA
机构
[1] NEWCASTLE GEN HOSP,DEPT REG MED PHYS,NEWCASTLE TYNE NE4 6BE,TYNE & WEAR,ENGLAND
[2] NEWCASTLE GEN HOSP,DEPT NEURORADIOL,NEWCASTLE TYNE NE4 6BE,TYNE & WEAR,ENGLAND
关键词
ULTRASOUND; DSA; CAROTID ARTERY; VERTEBRAL ARTERY;
D O I
10.1259/0007-1285-65-780-1069
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The use of duplex ultrasound with colour flow mapping is compared with that of intravenous digital subtraction angiography (IVDSA) in the investigation of carotid and vertebral artery disease. Ninety-nine carotid and vertebral arteries were examined independently by IVDSA and ultrasound for location and degree of disease in 30 men (mean age 58) and 20 women (mean age 53). For purposes of comparison the carotid tree was divided into six segments. In 46% of cases no disease was detected by either modality. In 36% of cases where disease was found, ultrasound found mild disease in arteries reported as normal by IVDSA. Both modalities detected the six cases of total occlusion found in the study. IVDSA underestimated five cases of major disease found by ultrasound at the bifurcation or in the bulb. Overall agreement in grading vessel segments was good, with 74.5% in complete agreement and 90.3% grading stenoses to within +/-25% of the other modality. There was good qualitative agreement in the findings for vertebral arteries. In four patients conventional arteriography was also available for comparison.
引用
收藏
页码:1069 / 1074
页数:6
相关论文
共 10 条
[1]  
CARDULLO PA, 1986, J DIAGNOST MED SONOG, V2, P63
[2]  
GLOVER JL, 1984, ARCH SURG-CHICAGO, V119, P664
[3]   THE VALIDATION OF DUPLEX SCANNING AND CONTINUOUS WAVE DOPPLER IMAGING - A COMPARISON WITH CONVENTIONAL ANGIOGRAPHY [J].
HAMES, TK ;
HUMPHRIES, KN ;
RATLIFF, DA ;
BIRCH, SJ ;
GAZZARD, VM ;
CHANT, ADB .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1985, 11 (06) :827-834
[4]   THE ACCURACY OF DUPLEX SCANNING IN THE EVALUATION OF EARLY CAROTID DISEASE [J].
HAMES, TK ;
RATLIFF, DA ;
HUMPHRIES, KN ;
GAZZARD, VM ;
BIRCH, SJ ;
CHANT, ADB .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1985, 11 (06) :819-825
[5]   DUPLEX CAROTID SONOGRAPHY - CRITERIA FOR STENOSIS, ACCURACY, AND PITFALLS [J].
JACOBS, NM ;
GRANT, EG ;
SCHELLINGER, D ;
BYRD, MC ;
RICHARDSON, JD ;
COHAN, SL .
RADIOLOGY, 1985, 154 (02) :385-391
[6]   CHARACTERIZATION OF CAROTID-ARTERY DISEASE - COMPARISON OF DUPLEX SCANNING WITH HISTOLOGY [J].
RATLIFF, DA ;
GALLAGHER, PJ ;
HAMES, TK ;
HUMPHRIES, KN ;
WEBSTER, JHH ;
CHANT, ADB .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1985, 11 (06) :835-840
[7]   CAROTID-ARTERY ATHEROMA - ULTRASOUND APPEARANCE IN SYMPTOMATIC AND ASYMPTOMATIC VESSELS [J].
STEFFEN, CM ;
GRAYWEALE, AC ;
BYRNE, KE ;
LUSBY, RJ .
AUSTRALIAN AND NEW ZEALAND JOURNAL OF SURGERY, 1989, 59 (07) :529-534
[8]  
STEINKE W, 1990, AM J NEURORADIOL, V11, P259
[9]   THE VALUE OF ANGIOGRAPHY IN CEREBROVASCULAR-DISEASE [J].
ZEITLER, E ;
SEYFARTH, W ;
RICHTER, EJ ;
RITTER, W ;
LEONHARDI, J .
THORACIC AND CARDIOVASCULAR SURGEON, 1989, 37 (04) :259-263
[10]   SPECTRUM ANALYSIS IN CAROTID SONOGRAPHY [J].
ZWIEBEL, WJ .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1987, 13 (10) :625-636