ELASTIC-MODULUS OF PREPARED CANINE JEJUNUM, A NEW VASCULAR GRAFT MATERIAL

被引:15
作者
HERBERT, ST [1 ]
BADYLAK, SF [1 ]
GEDDES, LA [1 ]
HILLBERRY, B [1 ]
LANTZ, GC [1 ]
KOKINI, K [1 ]
机构
[1] PURDUE UNIV, WILLIAM A HILLENBRAND BIOMED ENGN CTR, W LAFAYETTE, IN 47907 USA
关键词
BIOMATERIAL; MECHANICAL PROPERTIES; VASCULAR GRAFT;
D O I
10.1007/BF02368651
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The submucosal connective tissue of the jejunum has been shown to be suitable for use as a vascular graft in preliminary dog studies. To partially characterize the mechanical properties of this new graft material, longitudinal stress (sigma)-strain (epsilon)-data were obtained on 13 specimens of canine jejunum, stripped of its mucosal and external smooth-muscle layers. The ratio of stress to strain is the modulus of elasticity (E). It was found that the stress sigma-strain epsilon-data fitted the expression sigma = Kepsilon(alpha) very well. For a typical specimen sigma = 2.69 x 10(6) epsilon 2.33. The modulus of elasticity (E = sigma1-1/alpha K 1/alpha) was found to increase with increasing stress, ranging from about 2,000 to 9,000 mmHg. For the average specimen E = 573 sigma 0.57 sigma 0.57, where sigma is in mmHg, (1 mmHg = 133.3 Pascals).
引用
收藏
页码:727 / 733
页数:7
相关论文
共 19 条
  • [1] SMALL INTESTINAL SUBMUCOSA AS A LARGE DIAMETER VASCULAR GRAFT IN THE DOG
    BADYLAK, SF
    LANTZ, GC
    COFFEY, A
    GEDDES, LA
    [J]. JOURNAL OF SURGICAL RESEARCH, 1989, 47 (01) : 74 - 80
  • [2] DYNAMIC ELASTIC PROPERTIES OF ARTERIAL WALL
    BERGEL, DH
    [J]. JOURNAL OF PHYSIOLOGY-LONDON, 1961, 156 (03): : 458 - &
  • [3] STATIC ELASTIC PROPERTIES OF ARTERIAL WALL
    BERGEL, DH
    [J]. JOURNAL OF PHYSIOLOGY-LONDON, 1961, 156 (03): : 445 - &
  • [4] THE USE OF TUBES CONSTRUCTED FROM VINYON N-CLOTH IN BRIDGING ARTERIAL DEFECTS - EXPERIMENTAL AND CLINICAL
    BLAKEMORE, AH
    VOORHEES, AB
    [J]. ANNALS OF SURGERY, 1954, 140 (03) : 324 - 334
  • [5] CALLOW AD, 1986, ASTM STP, V698, P11
  • [6] MEASUREMENT OF VISCOELASTIC PROPERTIES OF ARTERIES IN LIVING DOG
    GOW, BS
    TAYLOR, MG
    [J]. CIRCULATION RESEARCH, 1968, 23 (01) : 111 - +
  • [7] CONTINUOUS MEASUREMENT OF AORTIC RADIUS CHANGE INVIVO WITH AN INTRA-AORTIC ULTRASONIC CATHETER
    HUGHES, DJ
    FEARNOT, NE
    BABBS, CF
    BOURLAND, JD
    GEDDES, LA
    EGGELTON, R
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1985, 23 (03) : 197 - 202
  • [8] KINLEY CE, 1974, SURGERY, V75, P28
  • [9] Lantz G C, 1990, J Invest Surg, V3, P217, DOI 10.3109/08941939009140351
  • [10] LYMAN DJ, 1973, ESSENTIAL PHYSICAL C, P115