SEPARATION OF HEAVY-METALS BY HIGH-SPEED COUNTERCURRENT CHROMATOGRAPHY

被引:13
作者
KITAZUME, E
SATO, N
SAITO, Y
ITO, Y
机构
[1] SHIMADZU CO LTD,ANALYT INSTRUMENTS RES LAB,NAKAGYO KU,KYOTO 604,JAPAN
[2] NHLBI,BIOPHYS CHEM LAB,BETHESDA,MD 20892
关键词
D O I
10.1021/ac00065a010
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Separation of heavy metal elements such as Co, Cu, Fe(II), Fe(III), Mg, and Ni was performed with a high-speed CCC coil planet centrifuge equipped with a multilayer coil. The two-phase solvent systems used for the separation were composed of n-heptane containing bis(2-ethylhexyl) phosphoric acid (stationary phase) and diluted citric acid (mobile phase), where the distribution ratios of the elements can be optimized by selecting a proper acid concentration. The mobile phase was eluted through the column at a flow rate of 5.0 mL/min while the apparatus was rotated at 800 rpm. Continuous detection of the metal elements was effected by measurement of the emission intensity with direct current plasma atomic emission spectrometry (DCP-AES), where the elution curve was obtained by on-line monitoring of each emission signal. Each metal element was well resolved at high partition efficiencies ranging from 200 to 3600 theoretical plates.
引用
收藏
页码:2225 / 2228
页数:4
相关论文
共 11 条
[1]  
FERREIRA HA, 1974, REV BRAS FARM, V55, P83
[2]   IMPROVED HIGH-SPEED COUNTERCURRENT CHROMATOGRAPH WITH 3 MULTILAYER COILS CONNECTED IN SERIES .3. EVALUATION OF SEMIANALYTICAL COLUMN WITH VARIOUS BIOLOGICAL SAMPLES AND INORGANIC ELEMENTS [J].
ITO, Y ;
OKA, H ;
KITAZUME, E ;
BHATNAGAR, M ;
LEE, YW .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1990, 13 (12) :2329-2349
[3]   IMPROVED HIGH-SPEED COUNTER-CURRENT CHROMATOGRAPH WITH 3 MULTILAYER COILS CONNECTED IN SERIES .2. SEPARATION OF VARIOUS BIOLOGICAL SAMPLES WITH A SEMIPREPARATIVE COLUMN [J].
ITO, Y ;
OKA, H ;
LEE, YW .
JOURNAL OF CHROMATOGRAPHY, 1990, 498 (01) :169-178
[4]   HIGH-SPEED COUNTERCURRENT CHROMATOGRAPHY [J].
ITO, Y .
CRC CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1986, 17 (01) :65-143
[5]   IMPROVED HIGH-SPEED COUNTERCURRENT CHROMATOGRAPH WITH 3 MULTILAYER COILS CONNECTED IN SERIES .1. DESIGN OF THE APPARATUS AND PERFORMANCE OF SEMIPREPARATIVE COLUMNS IN 2,4-DINITROPHENYL AMINO-ACID SEPARATION [J].
ITO, Y ;
OKA, H ;
SLEMP, JL .
JOURNAL OF CHROMATOGRAPHY, 1989, 475 :219-227
[6]   HIGH-SPEED PREPARATIVE COUNTERCURRENT CHROMATOGRAPHY WITH A COIL PLANET CENTRIFUGE [J].
ITO, Y ;
SANDLIN, J ;
BOWERS, WG .
JOURNAL OF CHROMATOGRAPHY, 1982, 244 (02) :247-258
[7]  
ITO Y, 1988, COUNTERCURRENT CHROM, pCH3
[8]  
KABASAWA Y, 1974, Z BUNSEKI KAGAKU, V23, P89
[9]   SEPARATION OF RARE-EARTH ELEMENTS BY HIGH-SPEED COUNTERCURRENT CHROMATOGRAPHY [J].
KITAZUME, E ;
BHATNAGAR, M ;
ITO, Y .
JOURNAL OF CHROMATOGRAPHY, 1991, 538 (01) :133-140
[10]  
KITAZUME E, 1990, P INT TRACE ANAL S S, P103