STAIR-STEP ARTIFACTS IN 3-DIMENSIONAL HELICAL CT - AN EXPERIMENTAL-STUDY

被引:92
作者
WANG, G
VANNIER, MW
机构
[1] Division of Radiology Research, Mallinckrodt Institute of Radiology, Washington Univ. School of Medicine, St Louis, MO 63110
关键词
COMPUTED TOMOGRAPHY (CT); ARTIFACT; HELICAL TECHNOLOGY; 3-DIMENSIONAL; PHANTOMS;
D O I
10.1148/radiology.191.1.8134601
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: Stair-step artifacts in helical computed tomography (CT) are associated with inclined surfaces in longitudinal sections. The authors investigated the origin and the characteristics of the artifacts. MATERIALS AND METHODS: A cone phantom and a skull were dry-scanned with a helical CT scanner, and images were reconstructed by using the half-scan interpolation algorithm with combinations of detector collimation (1 and 5 mm), table feed (1, 2, 5, and 10 mm), and reconstruction interval (1, 2, 5, and 10 mm). RESULTS: Stair-step artifacts were perceived in most instances. Stair-step artifacts arose from two sources: large reconstruction intervals and asymmetric helix interpolation, forming isoclosed curves and spirallike patterns in three-dimensional axial views, respectively. CONCLUSION: To eliminate the stair-step artifacts, both the collimation and the table feed should be less than the longitudinal dimension of the important feature on inclined surfaces, and the reconstruction interval should be less than the table feed. Adaptive interpolation may correct the artifacts.
引用
收藏
页码:79 / 83
页数:5
相关论文
共 15 条
[1]  
Bresler Y., 1989, P ICASSP, V3, P1472, DOI [10.1109/ICASSP.1989.266718, DOI 10.1109/ICASSP.1989.266718]
[2]   SPIRAL CT - DECREASED SPATIAL-RESOLUTION INVIVO DUE TO BROADENING OF SECTION-SENSITIVITY PROFILE [J].
BRINK, JA ;
HEIKEN, JP ;
BALFE, DM ;
SAGEL, SS ;
DICROCE, J ;
VANNIER, MW .
RADIOLOGY, 1992, 185 (02) :469-474
[3]  
BROOKS RA, 1977, J COMPUT ASSIST TOMO, V1, P191
[4]   COMPUTED-TOMOGRAPHY SCANNING WITH SIMULTANEOUS PATIENT TRANSLATION [J].
CRAWFORD, CR ;
KING, KF .
MEDICAL PHYSICS, 1990, 17 (06) :967-982
[5]   POTENTIAL ARTIFACTS ASSOCIATED WITH SCANNING PATTERN OF EMI SCANNER [J].
GOODENOUGH, DJ ;
WEAVER, KE ;
DAVIS, DO .
RADIOLOGY, 1975, 117 (03) :615-619
[6]   SPIRAL VOLUMETRIC CT WITH SINGLE-BREATH-HOLD TECHNIQUE, CONTINUOUS TRANSPORT, AND CONTINUOUS SCANNER ROTATION [J].
KALENDER, WA ;
SEISSLER, W ;
KLOTZ, E ;
VOCK, P .
RADIOLOGY, 1990, 176 (01) :181-183
[7]   PHYSICAL PERFORMANCE-CHARACTERISTICS OF SPIRAL CT SCANNING [J].
KALENDER, WA ;
POLACIN, A .
MEDICAL PHYSICS, 1991, 18 (05) :910-915
[8]   EVALUATION OF SECTION SENSITIVITY PROFILES AND IMAGE NOISE IN SPIRAL CT [J].
POLACIN, A ;
KALENDER, WA ;
MARCHAL, G .
RADIOLOGY, 1992, 185 (01) :29-35
[9]  
POLACIN A, IN PRESS MED PHYS
[10]  
PROKOP M, 1992, RADIOLOGY, V184, P127