Objective, non-invasive examination, techniques in addition to clinical parameters, are required to follow-up the wound healing of flaps. With the new laser Doppler Scanner (LDI DIM 1.0 Lisca Development AB, Sweden) it is possible, for the first time, to measure and image the microcirculation continuously, non-invasively and without contact with the wound, in an area of 12 cm square maximum. We performed measurements and simultaneous two-dimensional imaging of the microcirculation 24, 48, 72 h and 5 and 14 days postoperatively in 20 patients, who had had reconstruction procedures performed using random or axial pattern flaps. The perfusion diagrams were correlated to the clinical appearance. Necrotic areas, venous stasis and normal course of wound healing can be clearly visualized and differentiated from one another. The new laser Doppler imaging system seems to be an excellent aid for following up and planning of flaps in plastic and reconstructive surgery.
引用
收藏
页码:301 / 306
页数:6
相关论文
共 20 条
[1]   FREE FLAP MONITORING USING A MICROCOMPUTER LINKED TO A LASER DOPPLER FLOWMETER [J].
BRUCECHWATT, AJ .
BRITISH JOURNAL OF PLASTIC SURGERY, 1986, 39 (02) :229-238
[2]  
FISCHER J C, 1985, Microsurgery, V6, P238, DOI 10.1002/micr.1920060410
[3]  
HEDEN G, 1985, MICROSURG, V6, P11
[4]   LASER DOPPLER MONITORING OF FREE MICROVASCULAR FLAPS IN MAXILLOFACIAL SURGERY [J].
HELLNER, D ;
SCHMELZLE, R .
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 1993, 21 (01) :25-29
[5]  
HOVIUS SER, 1989, 1ST EUR C HAND SURG
[6]  
JENKINS S D, 1987, Journal of Reconstructive Microsurgery, V3, P281, DOI 10.1055/s-2007-1006996
[7]  
JONES BM, 1982, BR J PLAST SURG RES, V43, P147
[8]   VENOUS OUTFLOW OBSTRUCTION IN MYOCUTANEOUS FLAPS - CHANGES IN MICROCIRCULATION DETECTED BY THE PERFUSION FLUOROMETER AND LASER DOPPLER [J].
LIU, AJ ;
CUMMINGS, CW ;
TRACHY, RE .
OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 1986, 94 (02) :164-168
[9]   EVALUATION OF A LASER DOPPLER FLOWMETER FOR MEASUREMENT OF TISSUE BLOOD-FLOW [J].
NILSSON, GE ;
TENLAND, T ;
OBERG, PA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1980, 27 (10) :597-604
[10]  
Nilsson GE, 1980, IEEE T BIOMED ENG, V27, P1