MONITORING PHENYTOIN THERAPY USING CITRIC ACID-STIMULATED SALIVA IN INFANTS AND CHILDREN

被引:22
作者
LIFSHITZ, M
BENZVI, Z
GORODISCHER, R
机构
[1] SOROKA MED CTR,DIV PEDIAT,IL-84101 BEER SHEVA,ISRAEL
[2] SOROKA MED CTR,CLIN PHARMACOL UNIT,IL-84101 BEER SHEVA,ISRAEL
[3] BEN GURION UNIV NEGEV,FAC HLTH SCI,IL-84105 BEER SHEVA,ISRAEL
关键词
Phenytoin monitoring; Plasma phenytoin; Saliva phenytoin;
D O I
10.1097/00007691-199007000-00006
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Two factors have limited the use of saliva in monitoring phenytoin therapy: availability of adequate volume of clear saliva and lack of a sensitive phenytoin assay. The applicability of citric acid-stimulated saliva and of a sensitive analytical assay (fluorescence polarization immunoassay, “TDx” Abbott) was evaluated in this study. Phenytoin was measured in paired plasma-saliva specimens from epileptic children during the long-term or the initial phase of phenytoin therapy. Analysis was carried out in plasma and in the clear supernatant of saliva (following centrifugation). Pooled-estimate SD of the analytical assay variability was 0.175 μg/ml for plasma total phenytoin, 0.063 for plasma free phenytoin, and 0.009 for saliva phenytoin. Recovery measurements of phenytoin spiked into saliva samples gave a coefficient of variation of less than 5%. Correlations between saliva and total plasma phenytoin levels and between saliva and free plasma phenytoin levels were strong and highly significant (r = 0.99, p< 0.01). The percentage of temporal fluctuation (as determined by saliva phenytoin profiles) during 10-24 h ranged between 25.5-177 (mean, 58.3; SD, 47.3). Ratios of plasma total phenytoin/saliva phenytoin and of plasma free phenytoin/saliva phenytoin levels were 9.54 ± 1.05 and 0.71 ± 0.09, respectively. Dialysis experiments showed no binding of phenytoin to saliva supernatant. The greater saliva phenytoin concentrations as compared to plasma free phenytoin concentrations could be due to active transport of phenytoin from plasma to saliva. Measurement of phenytoin in citric acid-stimulated saliva by fluorescent polarization immunoassay is a reliable, noninvasive, and convenient method for monitoring phenytoin therapy in children. © 1990 Raven Press, Ltd., New York.
引用
收藏
页码:334 / 338
页数:5
相关论文
共 23 条
[1]  
ALLEN MA, 1976, J PHARMACOL EXP THER, V197, P408
[2]  
ANAVEKAR SN, 1978, CLIN PHARMACOL THER, V24, P629
[3]   EVALUATION OF AN ULTRAFILTRATION FLUORESCENCE POLARIZATION IMMUNOASSAY FOR MONITORING UNBOUND PHENYTOIN [J].
ARGYLE, JC ;
KINNIBURGH, DW ;
COSTA, R ;
JENNISON, T .
THERAPEUTIC DRUG MONITORING, 1984, 6 (01) :117-120
[4]  
AVIRAM M, 1987, PEDIATRICS, V80, P897
[5]  
BACON CJ, 1978, BR J CLIN PHARM, V6, P89
[6]   IDENTIFYING PATIENTS WHO MIGHT BENEFIT FROM FREE PHENYTOIN MONITORING [J].
BAIRDLAMBERT, J ;
MANGLICK, MP ;
WALL, M ;
BUCHANAN, N .
THERAPEUTIC DRUG MONITORING, 1987, 9 (02) :134-138
[7]   DETECTION OF CORTICOSTEROID BINDING GLOBULIN IN PAROTID FLUIDS - EVIDENCE FOR THE PRESENCE OF BOTH PROTEIN-BOUND AND NON-PROTEIN-BOUND (FREE) STEROIDS IN UNCONTAMINATED SALIVA [J].
CHU, FW ;
EKINS, RP .
ACTA ENDOCRINOLOGICA, 1988, 119 (01) :56-60
[8]  
EADY MJ, 1973, P AUST ASSOC NEUROL, V10, P53
[9]   SALIVA PHENOBARBITAL AND PHENYTOIN CONCENTRATIONS IN EPILEPTIC ADOLESCENTS [J].
FRIEDMAN, IM ;
LITT, IF ;
HENSON, R ;
HOLTZMAN, D ;
HALVERSON, D .
JOURNAL OF PEDIATRICS, 1981, 98 (04) :645-647
[10]   SALIVARY ANTICONVULSANT LEVELS IN CHILDREN - A COMPARISON OF METHODS [J].
GOLDSMITH, RF ;
OUVRIER, RA .
THERAPEUTIC DRUG MONITORING, 1981, 3 (02) :151-157