STEREOTAXIC FINE-NEEDLE ASPIRATION OF LOW-SUSPICION, NONPALPABLE BREAST NODULES - VALID ALTERNATIVE TO FOLLOW-UP MAMMOGRAPHY

被引:14
作者
FRANQUET, T
COZCOLLUELA, R
DEMIGUEL, C
机构
[1] HOSP VIRGEN DEL CAMINO,DEPT PATHOL,PAMPLONA,SPAIN
[2] HOSP VIRGEN DEL CAMINO,DEPT RADIOL,PAMPLONA,SPAIN
关键词
BREAST; BIOPSY; BREAST NEOPLASMS; DIAGNOSIS;
D O I
10.1148/radiology.183.3.1584910
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Seventy "low-suspicion," nonpalpable solid breast nodules were evaluated with stereotaxic fine-needle aspiration with cytologic analysis as an alternative to follow-up mammography. Sonography was performed in all cases to determine the solid nature of the nodules. Eight cysts were incorrectly classified with sonography, corresponding to atypical cysts; in such cases, however, stereotaxic fine-needle aspiration not only enabled the diagnosis, but was therapeutic as well. Fifty-eight of 70 breast aspirates (83%) yielded adequate cellular material for cytologic interpretation. A specific cytologic diagnosis was made in 52 cases (51 benign, one malignant). Insufficient cytologic material was obtained in 12 cases (17%). These results should help establish the validity of stereotaxic fine-needle aspiration with cytologic analysis as an alternative to follow-up mammography in patients with low-suspicion, solid breast nodules, reducing radiation exposure, patient anxiety, unnecessary biopsies, and costs.
引用
收藏
页码:635 / 637
页数:3
相关论文
共 18 条
[1]   NONPALPABLE, PROBABLY BENIGN BREAST-LESIONS - FOLLOW-UP STRATEGIES AFTER INITIAL DETECTION ON MAMMOGRAPHY [J].
ADLER, DD ;
HELVIE, MA ;
IKEDA, DM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 155 (06) :1195-1201
[2]   STEREOTACTIC FINE-NEEDLE BIOPSY IN 2594 MAMMOGRAPHICALLY DETECTED NON-PALPABLE LESIONS [J].
AZAVEDO, E ;
SVANE, G ;
AUER, G .
LANCET, 1989, 1 (8646) :1033-1036
[3]  
BRENNER RJ, 1989, RADIOLOGY, V171, P605
[4]   NONPALPABLE LESIONS DETECTED WITH MAMMOGRAPHY - REVIEW OF 512 CONSECUTIVE CASES [J].
CIATTO, S ;
CATALIOTTI, L ;
DISTANTE, V .
RADIOLOGY, 1987, 165 (01) :99-102
[5]   NONPALPABLE BREAST-TUMORS - DIAGNOSIS WITH STEREOTAXIC LOCALIZATION AND FINE-NEEDLE ASPIRATION [J].
DOWLATSHAHI, K ;
GENT, HJ ;
SCHMIDT, R ;
JOKICH, PM ;
BIBBO, M ;
SPRENGER, E .
RADIOLOGY, 1989, 170 (02) :427-433
[6]   NEEDLE LOCALIZATION AND FINE-NEEDLE ASPIRATION BIOPSY OF NONPALPABLE BREAST-LESIONS WITH USE OF STANDARD AND STEREOTACTIC EQUIPMENT [J].
EVANS, WP ;
CADE, SH .
RADIOLOGY, 1989, 173 (01) :53-56
[7]   MAMMOGRAPHY-GUIDED STEREOTAXIC FINE-NEEDLE ASPIRATION CYTOLOGY OF NONPALPABLE BREAST-LESIONS - PROSPECTIVE COMPARISON WITH SURGICAL BIOPSY RESULTS [J].
FAJARDO, LL ;
DAVIS, JR ;
WIENS, JL ;
TREGO, DC .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 155 (05) :977-981
[8]   BREAST MASSES - US-GUIDED FINE-NEEDLE ASPIRATION BIOPSY [J].
FORNAGE, BD ;
FAROUX, MJ ;
SIMATOS, A .
RADIOLOGY, 1987, 162 (02) :409-414
[9]   NONPALPABLE BREAST-LESIONS - RECOMMENDATIONS FOR BIOPSY BASED ON SUSPICION OF CARCINOMA AT MAMMOGRAPHY [J].
HALL, FM ;
STORELLA, JM ;
SILVERSTONE, DZ ;
WYSHAK, G .
RADIOLOGY, 1988, 167 (02) :353-358
[10]   MAMMOGRAPHIC FOLLOW-UP OF LOW-SUSPICION LESIONS - COMPLIANCE RATE AND DIAGNOSTIC YIELD [J].
HELVIE, MA ;
PENNES, DR ;
REBNER, M ;
ADLER, DD .
RADIOLOGY, 1991, 178 (01) :155-158