ANATOMY AND STRENGTH OF THE TUNICA ALBUGINEA - ITS RELEVANCE TO PENILE PROSTHESIS EXTRUSION

被引:71
作者
HSU, GL [1 ]
BROCK, G [1 ]
MARTINEZPINEIRO, L [1 ]
VONHEYDEN, B [1 ]
LUE, TF [1 ]
TANAGHO, EA [1 ]
机构
[1] UNIV CALIF SAN FRANCISCO, SCH MED, DEPT UROL, SAN FRANCISCO, CA 94143 USA
关键词
PENIS; PENILE PROSTHESIS; ANATOMY; PENILE ERECTION;
D O I
10.1016/S0022-5347(17)35214-X
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
In 7 male cadavers the anatomical structure, thickness and tensile strength of the tunica albuginea of the penis, measured at specific locations, were determined. The tunica is composed of inner circular and outer longitudinal layers made up of collagen bundles. The outer layer appears to determine, to a large extent, the variation in thickness and strength of the tunica. The ventral groove (found between the 5 and 7 o'clock positions), which houses the corpus spongiosum, lacks outer bundles and appears vulnerable to perforation. The thickness of the tunica measured at the 7, 9 and 11 o'clock positions was 0.8 +/- 0.1 mm., 1.2 +/- 0.2 mm. and 2.2 +/- 0.4 mm., respectively. Differences in the thickness of the tunica at specific locations were statistically significant (all p less than or equal to 0.018). Symmetrical measurements were nearly identical in a mirror image arrangement (3, 5 and 1 at the 9, 7 and 11 o'clock positions, respectively). The stress on the tunica at penetration (breaking point pressure) measured at the 7, 9 and 11 o'clock positions was 1.6 +/- 0.2 x 10(7) N./m.(2), 3.0 +/- 0.3 x 10(7) N./m.(2) and 4.5 +/- 0.5 x 10(7) N./m.(2), respectively. The strength and thickness of the tunica correlated in a statistically significant manner with location (r = 0.911 and p = 0.0001). The most vulnerable area is on the ventral aspect (which lacks the longitudinally directed outer layer bundles), where most prostheses tend to extrude. This finding supports our belief that prosthesis extrusion often has an anatomical basis and is not merely a phenomenon caused by infection or compression.
引用
收藏
页码:1205 / 1208
页数:4
相关论文
共 16 条
[1]   THE ELASTICITY AND THE TENSILE-STRENGTH OF TUNICA ALBUGINEA OF THE CORPORA CAVERNOSA [J].
BITSCH, M ;
KROMANNANDERSEN, B ;
SCHOU, J ;
SJONTOFT, E .
JOURNAL OF UROLOGY, 1990, 143 (03) :642-645
[2]  
Blum M D, 1989, Infect Dis Clin North Am, V3, P259
[3]  
CONDON EU, 1967, HDB PHYSICS, pA7
[4]   SALVAGE OF THE ERODED INFLATABLE PENILE PROSTHESIS - A NEW CONCEPT [J].
FURLOW, WL ;
GOLDWASSER, B .
JOURNAL OF UROLOGY, 1987, 138 (02) :312-314
[5]  
GELBARD M, 1993, PENIS, P244
[6]   PHALLOPLASTY [J].
GOODWIN, WE ;
SCOTT, WW .
JOURNAL OF UROLOGY, 1952, 68 (06) :903-908
[7]   COMPLICATIONS OF PENILE PROSTHESIS SURGERY FOR IMPOTENCE [J].
KAUFMAN, JJ ;
LINDNER, A ;
RAZ, S ;
FINNEY, RP .
JOURNAL OF UROLOGY, 1982, 128 (06) :1192-1194
[8]   COMPLICATIONS OF SMALL-CARRION PENILE PROSTHESIS [J].
KRAMER, SA ;
ANDERSON, EE ;
BREDAEL, JJ ;
PAULSON, DF .
UROLOGY, 1979, 13 (01) :49-51
[9]  
MELMAN A, 1988, SURG CLIN N AM, V68, P965
[10]   EXPERIENCE WITH SEMIRIGID ROD AND INFLATABLE PENILE PROSTHESES [J].
MONTAGUE, DK .