TENDON-RUPTURE AS A COMPLICATION OF SCREW FIXATION IN FRACTURES IN THE HAND - CASE-REPORT

被引:32
作者
FAMBROUGH, RA
GREEN, DP
机构
关键词
D O I
10.2106/00004623-197961050-00026
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Recently the technique of plate and screw fixation has been applied to fractures in the bones of the hands and feet. There have been few reported complications, and therefore an intraoperative complication is presented to show the narrow margin for technical error in the method of treatment as applied in the hand. A case of postoperative flexor tendon rupture due to laceration by an osteosynthesis screw is presented.
引用
收藏
页码:781 / 782
页数:2
相关论文
共 5 条
[2]  
HEIM U, 1974, SMALL FRAGMENT SET M
[3]  
Muller ME, 1970, MANUAL INTERNAL FIXA
[4]  
RUEDI TP, 1971, J TRAUM, V11, P381
[5]  
Simonetta C, 1970, Hand, V2, P43, DOI 10.1016/0072-968X(70)90034-3