THE ENERGY-CONSUMPTION OF DESK-TOP COMPUTERS - MEASUREMENT AND SAVINGS POTENTIAL

被引:12
作者
NEWSHAM, GR
TILLER, DK
机构
[1] Natl Research Council of Canada, Ottawa, Ont
关键词
D O I
10.1109/28.297924
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The energy consumption of desktop personal computers was studied at three Canadian Federal Government sites, and the potential for energy savings through power management investigated. The power draw of computers and their peripherals was measured using a portable meter, and use profiles were recorded using custom software. The measured plug loads were considerably lower than nameplate ratings. Use profiles from 94 computers indicated that there were long periods during both night and day when the computers were turned on but not being used, and it was predicted that significant energy savings could be achieved if electricity consumption was more closely tailored to actual usage. Two methods of realizing these savings were tested in the field. Stickers reminding users to switch off computers when they were not being used produced reductions in mean computer energy consumption of 14% over an eight week period. However, these savings diminished with time. An automatic power management system designed to switch off computers and periopherals after a user-specified period of inactivity produced reductions in mean computer energy consumption of 63%, while visual display unit mean energy consumption was reduced by 82%. These savings were maintained over an eight week period.
引用
收藏
页码:1065 / 1072
页数:8
相关论文
共 11 条
[1]  
HARRIS JP, 1992 PARTN ADM C IND
[2]  
LOVINS AB, 1990, ELECTRICITY SAVING O
[3]  
Norford L., 1989, ELECT EFFICIENT END, P427
[4]  
PATEL RF, 1993, USDOE DEAC0190CE2382
[5]  
PIETTE MA, 1991, 31308 LAWR BERK LAB
[6]  
Rea M.S., 1987, LIGHTING RES TECHNOL, V19, P81
[7]  
SEIGEL S, 1988, NONPARAMETRIC STATIS
[8]  
SZYDLOWSKI RF, 1994, PNL9061 PAC NW LAB R
[9]  
TILLER DK, 1993, CEA9101U829 REP NUMB
[10]  
WILINS CK, 1991, ASHRAE J SEP, P38