FLOW DEPENDENCE OF MEASURES OF AORTIC-STENOSIS SEVERITY DURING EXERCISE

被引:105
作者
BURWASH, IG [1 ]
PEARLMAN, AS [1 ]
KRAFT, CD [1 ]
MIYAKEHULL, C [1 ]
HEALY, NL [1 ]
OTTO, CM [1 ]
机构
[1] UNIV WASHINGTON,DEPT MED,DIV CARDIOL,SEATTLE,WA
关键词
D O I
10.1016/0735-1097(94)90118-X
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
Objectives. This study was designed to investigate the effect of altering transvalvular volume how rate on indexes of aortic stenosis severity (valve area, valve resistance, percent left ventricular stroke work loss) derived by using Doppler echocardiography. Background. Assessment of hemodynamic severity in aortic stenosis has been limited by the absence of an index that is independent of transvalvular flow rate. The traditional measurement of valve area by the Gorlin equation has been shown to vary with alterations in transvalvular flow. Recently, valve resistance and percent stroke work loss have been proposed as indexes that are relatively independent of flow. Although typically derived with invasive measurements, valve resistance and percent stroke work loss (in addition to continuity equation valve area) can be determined noninvasively with Doppler echocardiography. Methods. We performed 110 symptom-limited exercise studies in 66 asymptomatic patients with valvular aortic stenosis. Continuity equation valve area, valve resistance (the ratio between mean transvalvular pressure gradient and mean flow rate) and the steady component of percent stroke work loss (the ratio between mean transvalvular pressure gradient and left ventricular systolic pressure) were assessed by Doppler echocardiography at rest and immediately after exercise. Results, Mean transvalvular volume flow rate increased 24% (from [mean +/- SD] 319 +/- 80 to 400 +/- 140 ml/s, p < 0.0001); mean pressure gradient increased 36% (from 30 +/- 14 to 41 +/- 18 mm Hg, p < 0.0001); continuity equation aortic valve area increased 14% (from 138 +/- 0.50 to 1.58 +/- 0.69 cm(2), p < 0.0001); valve resistance increased 13% (from 137 +/- 81 to 155 +/- 97 dynes.s.cm(-5), p < 0.0001); and percent stroke work loss increased 17% (from 17.4 +/- 6.9% to 203 +/- 8.5%, p < 0.0001). The effects of flow on valve area, valve resistance and percent stroke work loss were independent of the presence of an aortic valve area less than or equal to or >1.0 cm(2) or reduced transvalvular flow rate (rest cardiac output <4.5 liters/min). Conclusions. In patients with asymptomatic aortic stenosis, Doppler echocardiographic measures of valve area, valve resistance and percent stroke work loss are how dependent. Flow dependence is observed with valve area less than or equal to or >1.0 cm(2) and in the presence of both normal and low transvalvular flow states. The potential effects of transvalvular flow should be considered when interpreting Doppler measures of aortic stenosis severity.
引用
收藏
页码:1342 / 1350
页数:9
相关论文
共 34 条
[1]
HEMODYNAMIC EFFECTS OF EXERCISE IN PATIENTS WITH AORTIC STENOSIS [J].
ANDERSON, FL ;
TSAGARIS, TJ ;
TIKOFF, G ;
THORNE, JL ;
SCHMIDT, AM ;
KUIDA, H .
AMERICAN JOURNAL OF MEDICINE, 1969, 46 (06) :872-&
[2]
HEMODYNAMIC EFFECTS OF EXERCISE IN ISOLATED VALCULAR AORTIC STENOSIS [J].
BACHE, RJ ;
WANG, Y ;
JORGENSEN, CR .
CIRCULATION, 1971, 44 (06) :1003-+
[3]
EFFECT OF STENOSIS GEOMETRY ON THE DOPPLER-CATHETER GRADIENT RELATION INVITRO - A MANIFESTATION OF PRESSURE RECOVERY [J].
BAUMGARTNER, H ;
SCHIMA, H ;
TULZER, G ;
KUHN, P .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (04) :1018-1025
[4]
BRAUNWALD E, 1992, HEART DISEASE, P1035
[5]
DEPENDENCE OF GORLIN FORMULA AND CONTINUITY EQUATION VALVE AREAS ON TRANSVALVULAR VOLUME FLOW-RATE IN VALVULAR AORTIC-STENOSIS [J].
BURWASH, IG ;
THOMAS, DD ;
SADAHIRO, M ;
PEARLMAN, AS ;
VERRIER, ED ;
THOMAS, R ;
KRAFT, CD ;
OTTO, CM .
CIRCULATION, 1994, 89 (02) :827-835
[6]
BURWASH IG, 1992, CIRCULATION, V86, P539
[7]
ECHOCARDIOGRAPHIC VOLUME FLOW AND STENOSIS SEVERITY MEASURES WITH CHANGING FLOW-RATE IN AORTIC-STENOSIS [J].
BURWASH, IG ;
FORBES, AD ;
SADAHIRO, M ;
VERRIER, ED ;
PEARLMAN, AS ;
THOMAS, R ;
KRAFT, C ;
OTTO, CM .
AMERICAN JOURNAL OF PHYSIOLOGY, 1993, 265 (05) :H1734-H1743
[8]
AORTIC-VALVE RESISTANCE AS AN ADJUNCT TO THE GORLIN FORMULA IN ASSESSING THE SEVERITY OF AORTIC-STENOSIS IN SYMPTOMATIC PATIENTS [J].
CANNON, JD ;
ZILE, MR ;
CRAWFORD, FA ;
CARABELLO, BA .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 20 (07) :1517-1523
[9]
HYDRAULIC ESTIMATION OF STENOTIC ORIFICE AREA - A CORRECTION OF THE GORLIN FORMULA [J].
CANNON, SR ;
RICHARDS, KL ;
CRAWFORD, M .
CIRCULATION, 1985, 71 (06) :1170-1178
[10]
INADEQUACY OF THE GORLIN FORMULA FOR PREDICTING PROSTHETIC VALVE AREA [J].
CANNON, SR ;
RICHARDS, KL ;
CRAWFORD, MH ;
FOLLAND, ED ;
PIERPONT, G ;
SETHI, GK ;
HAMMERMEISTER, KE .
AMERICAN JOURNAL OF CARDIOLOGY, 1988, 62 (01) :113-116