USE OF CORRECTED RETENTION INDEXES BASED ON 1-NITROALKANE AND ALKYL ARYLKETONE SCALES FOR HPLC IDENTIFICATION OF BASIC DRUGS

被引:21
作者
BOGUSZ, M
NEIDLFISCHER, G
ADERJAN, R
机构
关键词
D O I
10.1093/jat/12.6.325
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Sixteen basic drugs were examined by HPLC (gradient elution in acetonitrile/phosphate buffer, pH 3.2, containing 0.05% nonylamine) with six different ODS-silica columns. The retention indices (RI) were calculated with alkyl arylketone and 1-nitroalkane scales and were subjected to correction, which enabled comparison of results from commercially different column packing materials. The correction procedure was successful for the 1-nitroalkane scale. The scale based on alkyl arylketones was of less use for basic drugs, because some of them eluted earlier than the first reference homologue. This made impossible the proper calculation and correction of RI values for drugs such as cocaine, diphenhydramine, doxepin, and promethazine. The correction procedure of RI values calculated against the series of 1-nitroalkanes is recommended as a method of standardization of HPLC data.
引用
收藏
页码:325 / 329
页数:5
相关论文
共 16 条
[1]   GAS-LIQUID-CHROMATOGRAPHIC RETENTION INDEXES OF 1318 SUBSTANCES OF TOXICOLOGICAL INTEREST ON SE-30 OR OV-1 STATIONARY PHASE [J].
ARDREY, RE ;
MOFFAT, AC .
JOURNAL OF CHROMATOGRAPHY, 1981, 220 (03) :195-252
[2]   RETENTION INDEX SCALE FOR LIQUID-LIQUID CHROMATOGRAPHY [J].
BAKER, JK ;
MA, CY .
JOURNAL OF CHROMATOGRAPHY, 1979, 169 (FEB) :107-115
[3]   LABORATORY TO LABORATORY REPRODUCIBILITY OF HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC RETENTION INDEXES [J].
BAKER, JK ;
CATES, LA ;
CORBETT, MD ;
HUBER, JW ;
LATTIN, DL .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1982, 5 (05) :829-839
[4]   IMPROVED STANDARDIZATION IN REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING 1-NITROALKANES AS A RETENTION INDEX SCALE [J].
BOGUSZ, M ;
ADERJAN, R .
JOURNAL OF CHROMATOGRAPHY, 1988, 435 (01) :43-53
[5]   CORRECTION OF RETENTION INDEX VALUES IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AS A TOOL FOR COMPARISON OF RESULTS OBTAINED WITH DIFFERENT OCTADECYL SILICA PHASES [J].
BOGUSZ, M .
JOURNAL OF CHROMATOGRAPHY, 1987, 387 :404-409
[6]   CORRECTED RETENTION INDEXES IN HPLC - THEIR USE FOR THE IDENTIFICATION OF ACIDIC AND NEUTRAL-DRUGS [J].
BOGUSZ, M ;
ADERJAN, R .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1988, 12 (02) :67-72
[7]  
DOLAN JW, 1987, INT LAB, V17, P66
[8]   A COLLABORATIVE STUDY TO INVESTIGATE THE RETENTION REPRODUCIBILITY OF BARBITURATES IN HPLC WITH A VIEW TO ESTABLISHING RETENTION DATABASES FOR DRUG IDENTIFICATION [J].
GILL, R ;
MOFFAT, AC ;
SMITH, RM ;
HURDLEY, TG .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1986, 24 (04) :153-159
[9]  
GILL R, 1987, J CHROMATOGR, V386, P65
[10]   COMPARISON OF COLUMNS FOR REVERSED-PHASE LIQUID-CHROMATOGRAPHY [J].
GOLDBERG, AP .
ANALYTICAL CHEMISTRY, 1982, 54 (02) :342-345