A NEW MOCK CIRCULATORY LOOP AND ITS APPLICATION TO THE STUDY OF CHEMICAL ADDITIVE AND AORTIC PRESSURE EFFECTS ON HEMOLYSIS IN THE PENN STATE ELECTRIC VENTRICULAR ASSIST DEVICE

被引:16
作者
GARRISON, LA
FRANGOS, JA
GESELOWITZ, DB
LAMSON, TC
TARBELL, JM
机构
[1] PENN STATE UNIV, DEPT CHEM ENGN, 155 FENSKE LAB, University Pk, PA 16802 USA
[2] PENN STATE UNIV, DEPT BIOENGN, University Pk, PA 16802 USA
关键词
ARTIFICIAL HEART; VENTRICULAR ASSIST DEVICE; MOCK FLOW LOOP; HEMOLYSIS; PLURONIC F-68; DEXTRAN; POLYOX; SEPARAN;
D O I
10.1111/j.1525-1594.1994.tb02222.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A new mock circulatory loop was developed for hemolysis studies associated with the Penn State electric ventricular assist device (EVAD). This flow loop has several advantages over previously designed loops. It is small enough to accommodate experiments in which only single units of blood are available, it is made out of biocompatible materials, it incorporates good geometry, and it provides normal physiological pressures and flows to both the aortic outlet and the venous inlet of the pumping device. Experiments with reduced aortic pressure but normal cardiac output showed that hemolysis in a loop with normal aortic blood pressure was significantly higher than that in a loop with lowered aortic pressure, thereby illustrating the importance of maintaining loop pressures as close as possible to those found in vivo. This data also imply that blood traveling through the left ventricle in an artificial heart may be subject to higher hemolysis rates than that traversing the right ventricle. Another set of experiments to determine the effects of 4 hemolysis or drag-reducing agents (Pluronic F-68, Dextran-40, Polyox WSR-301, and Praestol 2273TR) on blood trauma due to the EVAD and associated valves was performed. Results indicated that none of the additives significantly reduced hemolysis under the conditions found in the mock loop. Finally, a compilation of data gathered in these experiments showed that the index of hemolysis (IH) is dependent on hematocrit (HCT), which suggests that another parameter, IH/HCT, may be more suited to the quantification of hemolysis.
引用
收藏
页码:397 / 407
页数:11
相关论文
共 22 条
[1]  
ALMONDHIRY H, 1992, ARTIF ORGANS, V16, P83
[2]  
BALDWIN JT, 1991, T AM SOC ART INT ORG, V37, pM348
[3]  
BERNSTEIN EF, 1967, SURGERY, V61, P432
[4]  
BROOKSHIER KK, 1991, BIORHEOLOGY, V28, P569
[5]   DEXTRAN PROTECTION OF ERYTHROCYTES FROM LOW-PH-INDUCED HEMOLYSIS [J].
CUDD, A ;
ARVINTE, T ;
SCHULZ, B ;
NICOLAU, C .
FEBS LETTERS, 1989, 250 (02) :293-296
[6]  
DUCKO CT, 1994, IN PRESS ARTIF ORGAN
[7]   AORTIC VALVE REPLACEMENT IN PATIENTS OVER AGE OF 60 [J].
HENZE, A .
SCANDINAVIAN JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1974, 8 (01) :1-11
[8]   DECREASED POSTSTENOTIC FLOW DISTURBANCE DURING DRAG REDUCTION BY POLYACRYLAMIDE INFUSION WITHOUT INCREASED AORTIC BLOOD-FLOW [J].
HUTCHISON, KJ ;
CAMPBELL, JD ;
KARPINSKI, E .
MICROVASCULAR RESEARCH, 1989, 38 (01) :102-109
[9]  
JARVIS P, 1989, THESIS PENNSYLVANIA
[10]  
JARVIS P, 1991, T AM SOC ART INT ORG, V37, P27