学术探索
学术期刊
新闻热点
数据分析
智能评审
立即登录
DEMONSTRATION OF THE AUDITORY OSSICLES BY HIGH-RESOLUTION CT
被引:34
作者
:
LLOYD, GAS
论文数:
0
引用数:
0
h-index:
0
机构:
NATL HOSP,LYSHOLM RADIOL DEPT,LONDON WC1N 3BG,ENGLAND
NATL HOSP,LYSHOLM RADIOL DEPT,LONDON WC1N 3BG,ENGLAND
LLOYD, GAS
[
1
]
DUBOULAY, GH
论文数:
0
引用数:
0
h-index:
0
机构:
NATL HOSP,LYSHOLM RADIOL DEPT,LONDON WC1N 3BG,ENGLAND
NATL HOSP,LYSHOLM RADIOL DEPT,LONDON WC1N 3BG,ENGLAND
DUBOULAY, GH
[
1
]
PHELPS, PD
论文数:
0
引用数:
0
h-index:
0
机构:
NATL HOSP,LYSHOLM RADIOL DEPT,LONDON WC1N 3BG,ENGLAND
NATL HOSP,LYSHOLM RADIOL DEPT,LONDON WC1N 3BG,ENGLAND
PHELPS, PD
[
1
]
PULLICINO, P
论文数:
0
引用数:
0
h-index:
0
机构:
NATL HOSP,LYSHOLM RADIOL DEPT,LONDON WC1N 3BG,ENGLAND
NATL HOSP,LYSHOLM RADIOL DEPT,LONDON WC1N 3BG,ENGLAND
PULLICINO, P
[
1
]
机构
:
[1]
NATL HOSP,LYSHOLM RADIOL DEPT,LONDON WC1N 3BG,ENGLAND
来源
:
NEURORADIOLOGY
|
1979年
/ 18卷
/ 05期
关键词
:
Auditory ossicles;
Computerised tomography;
D O I
:
10.1007/BF00327687
中图分类号
:
R74 [神经病学与精神病学];
学科分类号
:
摘要
:
The high resolution CT scanning system introduced by EMI in 1978 has added a new dimension to computerised tomography in otology. The apparatus used for this study was an EMI CT 5005 body scanner adapted for head and neck scanning and incorporating a high resolution facility. The latter has proved most advantageous in areas of relatively high differential absorption, so that its application to the demonstration of abnormalities in the petrous temporal bone, and in particular middle ear disease has been very rewarding. Traumatic ossicular disruptions may now be demonstrated and the high contrast of CT often shows them better than conventional hypocycloidal tomography. The stapes is also better visualised and congenital abnormalities of its superstructure have been recorded. These studies have been achieved with a very acceptable level of radiation to the eye, lens and cornea and the technique is clearly a rival to conventional pluridirectional tomography in the assessment of the petrous temporal bone. With further design improvements high resolution CT could completely replace existing techniques. © 1979 Springer-Verlag.
引用
收藏
页码:243 / 248
页数:6
相关论文
共 3 条
[1]
RADIATION DOSE TO CRITICAL ORGANS DURING PETROUS TOMOGRAPHY
[J].
CHIN, FK
论文数:
0
引用数:
0
h-index:
0
CHIN, FK
;
ANDERSON, WB
论文数:
0
引用数:
0
h-index:
0
ANDERSON, WB
.
RADIOLOGY,
1970,
94
(03)
:623
-&
[2]
HOUNSFIELD GN, 1977, PICTURE QUALITY COMP, V1, P11
[3]
COMPARATIVE-STUDY OF SPECIAL PETROUS VIEWS AND TOMOGRAPHY IN DIAGNOSIS OF ACOUSTIC NEUROMAS
[J].
LLOYD, GAS
论文数:
0
引用数:
0
h-index:
0
机构:
ROY NATL THROAT NOSE & EAR HOSP,LONDON WC1X 8DA,ENGLAND
ROY NATL THROAT NOSE & EAR HOSP,LONDON WC1X 8DA,ENGLAND
LLOYD, GAS
.
BRITISH JOURNAL OF RADIOLOGY,
1976,
49
(587)
:975
-975
←
1
→
共 3 条
[1]
RADIATION DOSE TO CRITICAL ORGANS DURING PETROUS TOMOGRAPHY
[J].
CHIN, FK
论文数:
0
引用数:
0
h-index:
0
CHIN, FK
;
ANDERSON, WB
论文数:
0
引用数:
0
h-index:
0
ANDERSON, WB
.
RADIOLOGY,
1970,
94
(03)
:623
-&
[2]
HOUNSFIELD GN, 1977, PICTURE QUALITY COMP, V1, P11
[3]
COMPARATIVE-STUDY OF SPECIAL PETROUS VIEWS AND TOMOGRAPHY IN DIAGNOSIS OF ACOUSTIC NEUROMAS
[J].
LLOYD, GAS
论文数:
0
引用数:
0
h-index:
0
机构:
ROY NATL THROAT NOSE & EAR HOSP,LONDON WC1X 8DA,ENGLAND
ROY NATL THROAT NOSE & EAR HOSP,LONDON WC1X 8DA,ENGLAND
LLOYD, GAS
.
BRITISH JOURNAL OF RADIOLOGY,
1976,
49
(587)
:975
-975
←
1
→