NETWORK SWITCHING AND VOLTAGE EVALUATION USING AN EXPERT SYSTEM IN AC RAILWAY SYSTEMS

被引:9
作者
CHANG, CS [1 ]
CHAN, TT [1 ]
LEE, KK [1 ]
机构
[1] KOWLOON CANTON RAILWAY CORP,KCR HOUSE SHAN TIN,HONG KONG
来源
IEE PROCEEDINGS-B ELECTRIC POWER APPLICATIONS | 1992年 / 139卷 / 01期
关键词
SYSTEM PROTECTION; RAILWAY ELECTRIFICATION AND TRANSPORTATION; SWITCHES AND SWITCHING THEORY;
D O I
10.1049/ip-b.1992.0001
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The development and implementation of a Prolog expert system using computer graphics is reported for the on-line monitoring and control of the 50 Hz single-phase overhead current collection catenary system currently in operation in Hong Kong. Running as an on-line consultant on a personal computer, this expert system allows operating personnel to perform intelligent network switching on a graphic picture representing the whole of the catenary line system. Users are able to find out effects of their own choice of switching sequence by examining graphic displays. Valid switching brings about changes in display configurations and colours to record changes in the on/off status of circuit-breakers or isolators, or the relocation of supply points. The expert system alos checks against any invalid switching which causes a violation of interlocking rules, an isolation of overhead-line sections from the supply, or a phase-to-phase short-circuit of the utility system. Work to develop a methodology of evaluating voltages across crossovers which run between parallel overhead lines is also reported. A crossover with excessive voltages across it should not be used to divert a train owing to the risk of damaging insulators across the crossover. An accurate evaluation of crossover voltages usually involves the solution of a large set of simultaneous differential equations governing train timetables, controls, movements and power consumptions. It is shown how train consumptions may be referred to their nearest static busbars and the resultant admittance matrix does not include any moving busbars (trains). This 'reduced' matrix occupies only a very manageable memory for either a full power flow solution or any other approximate method of voltage evaluation.
引用
收藏
页码:1 / 12
页数:12
相关论文
共 12 条
[1]  
BRAMELLER A, 1976, SPARSITY
[2]  
CHAN TT, 1990, THESIS HONG KONG POL
[4]  
CHANG CS, 1991, IN PRESS IEE P B
[5]  
CHANG CS, 1987, SEP INT C RAILW ENG
[6]  
CHANG CS, 1988, APR IEE INT C
[7]  
Clocksin W. F., 1984, PROGRAMMING PROLOG
[8]  
Kowalski Robert, ARTIFICIAL INTELLIGE
[9]  
MALPAS J, 1987, PROLOG RELATIONAL LA
[10]  
Wood A., 1984, POWER SYSTEM GENERAT