THE DESALINATION OF A MIXED-SOLUTION OF AN AMINO-ACID AND AN INORGANIC SALT BY MEANS OF ELECTRODIALYSIS WITH CHARGE-MOSAIC MEMBRANES

被引:35
作者
SATO, K [1 ]
SAKAIRI, T [1 ]
YONEMOTO, T [1 ]
TADAKI, T [1 ]
机构
[1] TOHOKU UNIV,DEPT BIOCHEM & ENGN,AOBA KU,SENDAI,MIYAGI 980,JAPAN
关键词
CHARGE-MOSAIC MEMBRANES; AMINO ACIDS; DESALINATION; ELECTRODIALYSIS;
D O I
10.1016/0376-7388(94)00236-R
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
A new electrodialysis with charge-mosaic membranes was proposed to achieve efficient desalination of a mixed solution of an amino acid and an inorganic salt. For such a mixed solution, the conventional electrodialytic desalination with both cation- and anion-exchange membranes had resulted in a considerable loss of the amino acid through the membranes. In this method, however, the amino acid in the desalination channel of the electrodialyzer migrates away from the membranes so that the permeation loss of the amino acid through the membrane can be prevented. Batchwise desalination experiments by this method were carried out with a glutamic acid or arginine solution including NaCl under the condition of constant electric current density. Similar experiments by the conventional method were also carried out. As a result of comparing both methods, the amino acid loss in this method became much smaller than that in the conventional one. It was confirmed that this method was very useful for the desalination of an amino acid solution. The effects of operating conditions on the desalination process are also discussed.
引用
收藏
页码:209 / 216
页数:8
相关论文
共 20 条
[1]  
Chang, Nomura, Demineralization of skimmed milk by electrodialysis with ion exchange and acetylcellulose membrane, Maku, 12, (1987)
[2]  
Hiraoka, Tomizawa, Oguchi, Koutake, Demineralization of reconstituted cheese whey solution by electrodialysis — Effects of linear velocity and temperature on limiting current density, KAGAKU KOGAKU RONBUNSHU, 14, (1988)
[3]  
Hiraoka, Tomizawa, Oguchi, Suzuki, Koutake, Demineralization of rehydrated cheese whey by electrodialysis — Effects of deashing rates and solid concentration on limiting current density, KAGAKU KOGAKU RONBUNSHU, 17, (1991)
[4]  
Yamabe, Seno, Takai, Permeability of amino acids through ion-exchange membrane, J. Chem. Soc. Japan. Ind. Chem. Sect., 64, (1961)
[5]  
Itoi, Utsunomiya, Electrodialysis of aqueous solution of amino acid containing electrolyte by ion-exchange membrane, Reports of the Research Laboratory, 15, (1965)
[6]  
Miyaki, Satoh, Akazawa, Baba, Development of a computer-controlled electrodialysis system FRESALTOR<sup>®</sup> for a laboratory-scale desalting, J. TOSOH Res., 33, (1989)
[7]  
Itoh, Yoshizumi, Saeki, Sieving effect in electrodialysis with an ion exchange membrane, J. Membrane Sci., 27, (1986)
[8]  
Miyaki, Fujimoto, Charge-mosaic membrane — A practical method of fablication, Maku, 8, (1983)
[9]  
Fujimoto, Ohkoshi, Miyaki, Nagasawa, A new charge-mosaic membrane from a multiblock copolymer, Science, 224, (1984)
[10]  
Fujimoto, Ohkoshi, Miyaki, Nagasawa, Artificial membranes from multiblock copolymers. I. Fabrication of a charge-mosaic membrane and preliminary tests of dialysis and piezodialysis, J. Membrane Sci., 20, (1984)