VERIFICATION OF THE HEART-RATE THRESHOLD

被引:54
作者
BUNC, V [1 ]
HOFMANN, P [1 ]
LEITNER, H [1 ]
GAISL, G [1 ]
机构
[1] GRAZ UNIV,INST SPORTS SCI,GRAZ,AUSTRIA
来源
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY | 1995年 / 70卷 / 03期
关键词
ANAEROBIC THRESHOLD; CONCONI TEST; VENTILATORY THRESHOLD; LACTATE TURN POINT; ELECTROMYOGRAPHY;
D O I
10.1007/BF00238574
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Among the methods for determining anaerobic threshold (AT), the heart rate (HR) method seems to be the simplest. On the other hand, many conflicting results from comparing this method with others have been presented over the last 10 years. Therefore, the aim of this study was to compare the heart rate threshold (HRT) with the lactate turn point (LTP) - ''second'' break point of dependence of lactate (LA) to power output, ventilatory threshold (VT) and threshold determined by electromyography (EMG(AT)), all determined by the same exercise test and evaluated by the same computer algorithm. A group of 24 female students [mean age 20.5 (SD 1.6) years, maximal oxygen consumption 48.8 (SD 4.7) ml . kg(-1) min(-1)] performed an incremental exercise test on a cycle ergometer (modified Conconi test) starting with an initial power output (PO) of 40 W with intensity increments of 10 W . min-1 until the subjects were exhausted. The HRT, LTP and EMG(AT) determination was done by computer-aided break-point regression analysis from dependence of functional measures on PO. The same computer algorithm was used for VT determination from the relationship between ventilation (Ti) and oxygen uptake (VO2) or carbon dioxide output (VCO2). Nonsignificant differences were found between HRT [VO2 35.2 (SD 4.2) ml.kg(-1) min(-1); HR 170.8 (SD 5.5) beats . min(-1); LA 4.01 (SD 1.03) mmol . l(-1); PO 2.27 (SD 0.33) W . kg(-1)]; VT [VO2 35.1 (SD 3.7) ml . kg(-1) min(-1); HR 168.3 (SD 4.8) beats . min(-1); LA 3.87 (SD 1.17) mmol . l(-1); PO 2.22 (SD 0.27) W . kg(-1)]; EMG(AT) [VO2 35.6 (SD 4.1) ml . kg(-1) min(-1); HR 171.0 (SD 5.4) beats . min(-1); LA 4.11 (SD 0.98) mmol . l(-1); PO 2.30 (SD 0.31) W . kg(-1)] and LTP [VO2 35.3 (SD 4.1) ml . kg(-1) min(-1); HR 170.1 (SD 6.0) beats . min(-1); LA 3.99 (SD 0.76) mmol . l(-1); PO 2.27 (SD 0.29) W . kg(-1)]. Highly significant correlations (P < 0.01 in all cases) were found among all measurements made at threshold level in all the thresholds investigated. Correlation coefficients ranged in selected variables at different threshold levels from 0.842 to 0.872 in VO2 measured in ml . kg(-1) min(-1), from 0.784 to 0.912 for LA, from 0.648 to 0.857 for HR, and from 0.895 to 0.936 for PO measured in W . kg(-1). These findings have led us to conclude that HRT could be used as an alternative method of determining anaerobic threshold in untrained subjects.
引用
收藏
页码:263 / 269
页数:7
相关论文
共 38 条
  • [1] A COMPARISON OF 2 NONINVASIVE METHODS IN THE DETERMINATION OF THE ANAEROBIC THRESHOLD IN CHILDREN
    BARALDI, E
    ZANCONATO, S
    SANTUZ, PA
    ZACCHELLO, F
    [J]. INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 1989, 10 (02) : 132 - 134
  • [2] BROOKS GA, 1985, MED SCI SPORT EXER, V17, P22
  • [3] VENTILATORY THRESHOLD IN VARIOUS GROUPS OF HIGHLY TRAINED ATHLETES
    BUNC, V
    HELLER, J
    LESO, J
    SPRYNAROVA, S
    ZDANOWICZ, R
    [J]. INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 1987, 8 (04) : 275 - 280
  • [4] VENTILATORY THRESHOLD AND MECHANICAL EFFICIENCY IN ENDURANCE RUNNERS
    BUNC, V
    HELLER, J
    MORAVEC, P
    SPRYNAROVA, S
    [J]. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 1989, 58 (07) : 693 - 698
  • [5] BUNC V, 1984, PRAC LEK, V36, P127
  • [6] BUNC V, 1982, INT J SPORTS MED, V3, P11
  • [7] Kinetics of heart rate responses to exercise
    Bunc, Vaclav
    Heller, Jan
    Leso, Jiri
    [J]. JOURNAL OF SPORTS SCIENCES, 1988, 6 (01) : 39 - 48
  • [8] A COMPARISON OF GAS-EXCHANGE INDEXES USED TO DETECT THE ANAEROBIC THRESHOLD
    CAIOZZO, VJ
    DAVIS, JA
    ELLIS, JF
    AZUS, JL
    VANDAGRIFF, R
    PRIETTO, CA
    MCMASTER, WC
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1982, 53 (05) : 1184 - 1189
  • [9] DETERMINATION OF THE ANAEROBIC THRESHOLD BY A NON-INVASIVE FIELD-TEST IN RUNNERS
    CONCONI, F
    FERRARI, M
    ZIGLIO, PG
    DROGHETTI, P
    CODECA, L
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1982, 52 (04) : 869 - 873
  • [10] DEFINING HYPOXIA - A SYSTEMS VIEW OF VO2, GLYCOLYSIS, ENERGETICS, AND INTRACELLULAR PO-2
    CONNETT, RJ
    HONIG, CR
    GAYESKI, TEJ
    BROOKS, GA
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1990, 68 (03) : 833 - 842