A COMPARATIVE-STUDY OF SCATTER CORRECTION METHODS FOR SCINTIGRAPHIC IMAGES

被引:14
作者
BONNIN, F
BUVAT, I
BENALI, H
DIPAOLA, R
机构
[1] INSERM U66, Institut Gustave-Roussy, Villejuif Cedex, 39, rue Camille Desmoulins
来源
EUROPEAN JOURNAL OF NUCLEAR MEDICINE | 1994年 / 21卷 / 05期
关键词
SCATTER CORRECTION; TC-99M HYDROXYMETHYLENE DIPHOSPHONATE BONE SCINTIGRAPHY; SCATTER WINDOW SUBTRACTION; FACTOR ANALYSIS OF MEDICAL IMAGE SEQUENCES USING TARGET APEX-SEEKING;
D O I
10.1007/BF00171412
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Phantom studies have demonstrated that factor analysis of medical image sequences using target apex-seeking (FAMIS-TAS) applied to spectral scintigraphic image sequences is an efficient adaptive scatter correction method. We assessed the improvement in quality of clinical images using FAMIS-TAS as compared with two other scatter correction techniques: conventional 20% photopeak window (PW) and scatter window subtraction (SWS). Thirty normal technetium-99m hydroxymethylene diphosphonate bone scans were processed. Bone to soft tissue contrasts and signal-to-noise and contrast-to-noise ratios were measured. The overall image quality was evaluated using an observer testing questionnaire submitted to four physicians. Quantitative parameters showed that FAMIS-TAS images displayed the best bone to soft tissue contrasts and contrast-to-noise ratios, but the lowest signal-to-noise ratios. PW images presented the lowest contrasts and contrast-to-noise ratios, and the highest signal-to-noise ratios. SWS gave intermediate results. According to the observer testing results, PW images showed the lowest bone to soft tissue contrasts and the highest signal-to-noise ratios. FAMIS-TAS images showed the lowest signal-to-noise ratios. The images processed by the three methods displayed the same anatomical information.
引用
收藏
页码:388 / 393
页数:6
相关论文
共 24 条
[1]   A STATISTICAL-MODEL FOR THE DETERMINATION OF THE OPTIMAL METRIC IN FACTOR-ANALYSIS OF MEDICAL IMAGE SEQUENCES (FAMIS) [J].
BENALI, H ;
BUVAT, I ;
FROUIN, F ;
BAZIN, JP ;
DIPAOLA, R .
PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (08) :1065-1080
[2]   TARGET APEX-SEEKING IN FACTOR-ANALYSIS OF MEDICAL IMAGE SEQUENCES [J].
BUVAT, I ;
BENALI, H ;
FROUIN, F ;
BAZIN, JP ;
DIPAOLA, R .
PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (01) :123-138
[3]  
BUVAT I, 1992, EUR J NUCL MED, V19, P586
[4]  
BUVAT I, 1992, THESIS U PARIS 11
[5]   HANDLING OF DYNAMIC SEQUENCES IN NUCLEAR-MEDICINE [J].
DIPAOLA, R ;
BAZIN, JP ;
AUBRY, F ;
AURENGO, A ;
CAVAILLOLES, F ;
HERRY, JY ;
KAHN, E .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1982, 29 (04) :1310-1321
[6]  
FLOYD CE, 1985, J NUCL MED, V26, P403
[7]   MONTE-CARLO EVALUATION OF COMPTON SCATTER SUBTRACTION IN SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY [J].
FLOYD, CE ;
JASZCZAK, RJ ;
HARRIS, CC ;
GREER, KL ;
COLEMAN, RE .
MEDICAL PHYSICS, 1985, 12 (06) :776-778
[8]   ENERGY AND SPATIAL-DISTRIBUTION OF MULTIPLE ORDER COMPTON SCATTER IN SPECT - A MONTE-CARLO INVESTIGATION [J].
FLOYD, CE ;
JASZCZAK, RJ ;
HARRIS, CC ;
COLEMAN, RE .
PHYSICS IN MEDICINE AND BIOLOGY, 1984, 29 (10) :1217-1230
[9]   INTRODUCTION TO HOLOSPECTRAL IMAGING IN NUCLEAR-MEDICINE FOR SCATTER SUBTRACTION [J].
GAGNON, D ;
TODDPOKROPEK, A ;
ARSENAULT, A ;
DUPRAS, G .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1989, 8 (03) :245-250
[10]   GAMMA-CAMERA RADIONUCLIDE IMAGES - IMPROVED CONTRAST WITH ENERGY-WEIGHTED ACQUISITION [J].
HALAMA, JR ;
HENKIN, RE ;
FRIEND, LE .
RADIOLOGY, 1988, 169 (02) :533-538