EFFECTS OF ENDOTRACHEAL-TUBE LEAKS ON FUNCTIONAL RESIDUAL CAPACITY DETERMINATION IN INTUBATED NEONATES

被引:46
作者
FOX, WW [1 ]
SCHWARTZ, JG [1 ]
SHAFFER, TH [1 ]
机构
[1] UNIV PENN,SCH MED,DEPT PHYSIOL,PHILADELPHIA,PA 19174
关键词
D O I
10.1203/00006450-197901000-00013
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
The present study evaluates a new closed circuit helium (He) dilution technique for determination of endotracheal (ET) tube leakage and functional residual capacity (FRC) in neonates with ET tubes. By analytically relating the fall in He concentration due to mixing with that due to leakage, it is possible to predict the final equilibration concentration of He and, therefore, correct for ET tube leaks. The system (120 ml) contains an air pump, He meter, breathing bag in cylinder, a strip chart readout, and solenoid valve. Continuous positive airway pressure (CPAP) or ventilator pressure can be applied during testing. FRC measurements were performed on 13 neonates (700-4500 g) on CPAP with ET tubes. Leak rates were significantly higher (P < 0.001) on 3 cm H2O CPAP compared to 0 cm H2O CPAP. The mean’measured FRC 'was 53.5 ml at 3 cm H2O and 46.3 ml at 0 cm H2O CPAP. If gas leakage had not been considered in FRC calculations, the error in FRC could have been as high as 39% at 3 cm H2O CPAP and 18% at 0 cm HaO CPAP. Speculation: The present, technique provides a high degree of accuracy for determining FRC and ET tube leakage in critically ill infants on CPAP. Although measurements were not conducted on CPAP levels above 3 cm H2O, it is possible that higher levels of pressure may result in even greater leakage. Under these conditions FRC could only be determined accurately with this method. © 1979 International Pediatric Research Foundation, Inc.
引用
收藏
页码:60 / 64
页数:5
相关论文
共 26 条
[1]  
AULD PAM, 1963, J CLIN INVEST, V42, P478
[2]  
BATES DV, 1950, CLIN SCI, V9, P17
[3]  
BERGLUND G, 1956, Acta Paediatr, V45, P541, DOI 10.1111/j.1651-2227.1956.tb06913.x
[4]   OPTIMUM LEVELS OF CPAP FOR TRACHEAL EXTUBATION OF NEWBORN-INFANTS [J].
BERMAN, LS ;
FOX, WW ;
RAPHAELY, RC ;
DOWNES, JJ .
JOURNAL OF PEDIATRICS, 1976, 89 (01) :109-112
[5]  
BRISCOE WA, 1952, CLIN SCI, V11, P45
[6]   FACTORS AFFECTING PEDIATRIC ENDOTRACHEAL TUBE SIZE - A STATISTICAL ANALYSIS [J].
CHODOFF, P ;
HELRICH, M .
ANESTHESIOLOGY, 1967, 28 (04) :779-&
[7]   RAPID PLETHYSMOGRAPHIC METHOD FOR MEASURING THORACIC GAS VOLUME - COMPARISON WITH A NITROGEN WASHOUT METHOD FOR MEASURING FUNCTIONAL RESIDUAL CAPACITY IN NORMAL SUBJECTS [J].
DUBOIS, AB ;
BOTELHO, SY ;
BEDELL, GN ;
MARSHALL, R ;
COMROE, JH .
JOURNAL OF CLINICAL INVESTIGATION, 1956, 35 (03) :322-326
[8]   LUNG FUNCTION STUDIES .8. ANALYSIS OF ALVEOLAR VENTILATION BY PULMONARY N-2 CLEARANCE CURVES [J].
FOWLER, WS ;
CORNISH, ER ;
KETY, SS .
JOURNAL OF CLINICAL INVESTIGATION, 1952, 31 (01) :40-50
[9]  
FOX WW, 1977, PEDIATR RES, V11, P570, DOI 10.1203/00006450-197704000-01202
[10]   PULMONARY PHYSIOTHERAPY IN NEONATES - PHYSIOLOGIC CHANGES AND RESPIRATORY MANAGEMENT [J].
FOX, WW ;
SCHWARTZ, JG ;
SHAFFER, TH .
JOURNAL OF PEDIATRICS, 1978, 92 (06) :977-981