FIBRIN ANTIBIOTIC MIXTURES - AN INVITRO STUDY ASSESSING THE POSSIBILITY OF USING A BIOLOGIC CARRIER FOR LOCAL-DRUG DELIVERY

被引:52
作者
GRECO, F [1 ]
DEPALMA, L [1 ]
SPAGNOLO, N [1 ]
ROSSI, A [1 ]
SPECCHIA, N [1 ]
GIGANTE, A [1 ]
机构
[1] UNIV CATTOLICA SACRO CUORE, CTR BIOENGN, SCH MED, DEPT ORTHOPAED, I-00168 ROME, ITALY
来源
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH | 1991年 / 25卷 / 01期
关键词
D O I
10.1002/jbm.820250104
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An in vitro study assessing the kinetics of drug release from antibiotic-fibrin seal compounds and the antibacterial efficacy of the delivered drug has been performed. Antibiotic sensitivity and the amount of drug released was measured by means of agar diffusion test. Standard and experimental curves were established for each antibiotic and each bacterial test in order to evaluate the quantities of the drug released during each 24 h period. The reconstitution of lyophilized human fibrin with an aqueous solution containing an antibiotic resulted in only minor modification of the clotting process, with the exception of those solutions containing cefotaxim and mezlocillin which failed to clot altogether and were excluded from further study. The evaluation of the kinetics of elution of the antibiotics from the fibrin clots showed that all of the antibiotics had been almost completely released by 96 h. The delivered amount of each drug was enough to maintain the Minimal Inhibitory Concentration (MIC) until the 4th day of culture for the most of antibiotics, resulting in a prolonged release of the drug.
引用
收藏
页码:39 / 51
页数:13
相关论文
共 26 条
[1]   FIBRIN ADHESIVE SYSTEM (FAS) INFLUENCE ON BONE HEALING RATE - A MICRORADIOGRAPHICAL EVALUATION USING THE BONE-GROWTH CHAMBER [J].
ALBREKTSSON, T ;
BACH, A ;
EDSHAGE, S ;
JONSSON, A .
ACTA ORTHOPAEDICA SCANDINAVICA, 1982, 53 (05) :757-763
[2]   1ST CLINICAL-EXPERIENCE WITH HETEROLOGOUS CANCELLOUS BONE-GRAFTING COMBINED WITH THE FIBRIN ADHESIVE SYSTEM (FAS) [J].
ARBES, H ;
BOSCH, P ;
LINTNER, F ;
SALZER, M .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1981, 98 (03) :183-188
[3]  
BOHLER N, 1977, UNFALLHEILKUNDE, V80, P501
[4]   EXPERIMENTAL INVESTIGATIONS OF THE EFFECT OF THE FIBRIN ADHESIVE ON THE KIEL HETEROLOGOUS BONE-GRAFT [J].
BOSCH, P ;
LINTNER, F ;
ARBES, H ;
BRAND, G .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1980, 96 (03) :177-185
[5]  
Braun A, 1979, Hefte Unfallheilkd, V138, P294
[6]  
BRAUN A, 1981, HEFTE UNFALLHEIKD, V153, P83
[7]  
BUCHHOLZ HW, 1970, CHIRURG, V41, P511
[8]  
CHARNLEY J, 1970, Journal of Bone and Joint Surgery British Volume, V52, P340
[9]  
CHIELLINI E, 1985, BIOMATERIALI RICERCA, P81
[10]  
DEPALMA L, 1985, ARCH ORTHOP REUMATOL, V98, P179