摘要
Errors in the measurement of the mean velocity of pulsatile velocity waveforms with ungated phase-contrast techniques were studied theoretically and experimentally. Waveforms consisting of a constant and two sinusoidal components were analyzed. Variations in magnitude and phase of the vascular magnetic resonance (MR) signal resulted in errors, the severity of which increased when either factor increased. Magnitude variations always resulted in overestimation. The general shape of the waveform greatly influenced the error, with certain waveforms producing greater inherent error than others. Experimental measurements were performed, validating the predicted sensitivity of these errors to changes in imaging parameters, including TR and flow-encoding sensitivity. Errors generally became more severe with increased flow-encoding sensitivity. The theoretical and experimental results suggest that accurate mean velocity measurements in many vessels of the body-with acquisition times of less than 15 seconds-should be attainable with ungated imaging techniques and with careful selection of relevant imaging parameters.
引用
收藏
页码:387 / 394
页数:8
相关论文
共 11 条
[1]  
Firmin DN, Klipstein RH, Hounsfield GL, Paley MP, Longmore DB, Echo‐planar high‐resolution flow velocity mapping, Magn Reson Med, 12, pp. 316-327, (1989)
[2]  
Pelc NJ, Shimakawa A, Glover GH, Phase contrast cine MRI (abstr), Book of abstracts: Society of Magnetic Resonance in Medicine 1989, (1989)
[3]  
Weisskoff RM, Crawley AP, Wedeen V, Flow sensitivity and flow compensation in instant imaging (abstr), Book of abstracts: Society of Magnetic Resonance in Medicine 1990, (1990)
[4]  
Duerk JL, Simonetti OP, Theoretical aspects of motion sensitivity and compensation in echo‐planar imaging, JMRI, 1, pp. 643-650, (1991)
[5]  
Butts RK, Riederer SJ, Analysis of flow effects in echoplanar imaging, JMRI, 2, pp. 285-293, (1992)
[6]  
Atkinson DJ, Edelman RR, Cineangiography of the heart in a single breath hold with a segmented TurboFLASH sequence, Radiology, 178, pp. 357-360, (1991)
[7]  
Riederer SJ, Wright RC, Ehman RL, Et al., Real‐time interactive color flow MR imaging, Radiology, 181, pp. 33-39, (1991)
[8]  
Hangiandreou NJ, Wright RC, Rossman PJ, Riederer SJ, Analysis of phase contrast measurements of time‐varying velocity waveforms (abstr), Works in progress: Society of Magnetic Resonance in Medicine 1991, (1991)
[9]  
Perman WH, Moran PR, Moran RA, Bernstein MA, Artifacts from pulsatile flow in MR imaging, J Comput Assist Tomogr, 10, pp. 473-483, (1986)
[10]  
Cho MH, Kim WS, Cho ZH, CSF flow artifact reduction using cardiac cycle ordered phase‐encoding method, Magn Reson Imaging, 8, pp. 395-405, (1990)