DETERMINATION OF POLAR ANILINE DERIVATIVES IN AQUEOUS ENVIRONMENTAL-SAMPLES USING ONLINE LIQUID-CHROMATOGRAPHIC PRECONCENTRATION TECHNIQUES

被引:30
作者
HENNION, MC
SUBRA, P
COQUART, V
ROSSET, R
机构
[1] Laboratoire de Chimie Analytique, Ecole Supérieure de Physique et Chimie de Paris, Paris Cédex 05, F-75231, 10, rue Vauquelin
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 1991年 / 339卷 / 07期
关键词
D O I
10.1007/BF00323805
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
On-line precolumn sample handling is used to enrich polar aniline derivatives in order to preconcentrate them prior to their separation. Liquid-solid extraction is possible with a cation-exchanger precolumn after acidification of water samples at pH 3 and a clean-up in order to remove the high amounts of inorganic cations present in natural samples. Since inorganic removal cannot be total, overloading of the ion exchanger occurs rapidly. The volume which can be directly percolated through the cation-exchanger precolumn cannot exceed 30 ml and the amount preconcentrated is not sufficient for a determination at the 100 ppt level. A two-step preconcentration procedure is carried out in order to increase the sample volume: the direct percolation of samples through the cation-exchanger precolumn is avoided and the clean-up step is no longer necessary. Aniline derivatives are preconcentrated in their neutral form at pH 7 by a 9-cm long column packed with the copolymer-based PRP-1 sorbent; then, a small volume of water-methanol at pH 2 allows the cationic compounds alone to be desorbed from the PRP-1 column in their protonated form and to be transferred to a 1-cm long cation-exchanger precolumn. This precolumn is then coupled to an analytical C18 column and its content on-line analysed by an acetonitrile gradient. The PRP-1 column acts as a powerful filter to many neutral interferents and aniline derivatives can be thus determined from 150-ml drinking water samples
引用
收藏
页码:488 / 493
页数:6
相关论文
共 16 条
[1]  
FREI RW, 1987, ANALUSIS, V15, P59
[2]   DETERMINATION OF ANILINE DERIVATIVES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION [J].
GEERDINK, RB .
JOURNAL OF CHROMATOGRAPHY, 1988, 445 (01) :273-281
[3]   OPTIMIZATION OF PRECOLUMN DESIGN IN LIQUID-CHROMATOGRAPHY [J].
GOEWIE, CE ;
NIELEN, MWF ;
FREI, RW ;
BRINKMAN, UAT .
JOURNAL OF CHROMATOGRAPHY, 1984, 301 (02) :325-334
[4]   USE OF PYROCARBON SORBENTS FOR TRACE ENRICHMENT OF POLAR COMPOUNDS FROM AQUEOUS SAMPLES WITH ONLINE HPLC ANALYSIS [J].
GOLKIEWICZ, W ;
WERKHOVENGOEWIE, CE ;
BRINKMAN, UAT ;
FREI, RW ;
COLIN, H ;
GUIOCHON, G .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1983, 21 (01) :27-33
[5]   TRACE-LEVEL DETERMINATION OF PHENOL BY LIQUID-CHROMATOGRAPHY WITH ONLINE PRECOLUMN TECHNOLOGY AND FLUORESCENCE DETECTION [J].
NIELEN, MWF ;
DEJONG, J ;
FREI, RW ;
BRINKMAN, UAT .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1986, 25 (1-3) :37-48
[6]   METAL-LOADED SORBENTS FOR SELECTIVE ONLINE SAMPLE HANDLING AND TRACE ENRICHMENT IN LIQUID-CHROMATOGRAPHY [J].
NIELEN, MWF ;
VANINGEN, HE ;
VALK, AJ ;
FREI, RW ;
BRINKMAN, UAT .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1987, 10 (04) :617-633
[7]   INDUSTRIAL WASTE-WATER ANALYSIS BY LIQUID-CHROMATOGRAPHY WITH PRECOLUMN TECHNOLOGY AND DIODE-ARRAY DETECTION [J].
NIELEN, MWF ;
BRINKMAN, UAT ;
FREI, RW .
ANALYTICAL CHEMISTRY, 1985, 57 (04) :806-810
[8]   USE OF A PRECOLUMN PACKED WITH MERCURY(II)-8-HYDROXYQUINOLINE FOR THE SELECTIVE ONLINE TRACE ENRICHMENT OF 2-MERCAPTOBENZIMIDAZOLE IN LIQUID-CHROMATOGRAPHY [J].
NIELEN, MWF ;
BLEEKER, R ;
FREI, RW ;
BRINKMAN, UAT .
JOURNAL OF CHROMATOGRAPHY, 1986, 358 (02) :393-400
[9]   USE OF CATION EXCHANGERS FOR THE ONLINE PRECONCENTRATION OF POLAR ANILINES IN LIQUID-CHROMATOGRAPHY [J].
NIELEN, MWF ;
FREI, RW ;
BRINKMAN, UAT .
JOURNAL OF CHROMATOGRAPHY, 1984, 317 (DEC) :557-567
[10]   APPLICATIONS OF ONLINE PRECOLUMN TECHNOLOGY TO WATER-QUALITY CONTROL [J].
SUBRA, P ;
HENNION, MC ;
ROSSET, R ;
FREI, RW .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1989, 37 (01) :45-62