FACTORS AFFECTING DETECTION OF BRUCELLA-MELITENSIS BY BACTEC NR730, A NONRADIOMETRIC SYSTEM FOR HEMOCULTURES

被引:23
作者
GAMAZO, C [1 ]
VITAS, AI [1 ]
LOPEZGONI, I [1 ]
DIAZ, R [1 ]
MORIYON, I [1 ]
机构
[1] UNIV NAVARRA,CLIN UNIV,DEPT MICROBIOL,E-31080 PAMPLONA,SPAIN
关键词
D O I
10.1128/JCM.31.12.3200-3203.1993
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
The detection of Brucella bacteremia by subculture does not always correlate with a positive signal in the BACTEC NR730 nonradiometric system (Becton Dickinson Diagnostic Instrument Systems, Sparks, Md.). The effect of the inoculum size, pH, sodium polyanetbolesulfonate, carbon sources (i-erythritol, sodium pyruvate, monosodium glutamate, D-glucose, and L-alanine), and urea in the release of CO, was evaluated by using the reference strain Brucella melitensis 16M. In standard NR6 vials with or without blood, inocula 5 to 10 times larger (at least 265 CFU per vial) than those usually found in the blood of patients with brucellosis were necessary to produce a positive growth value (GV) in 4 days or less, and similar results were obtained with vials supplemented with the substrates listed above. GVs were consistently lower in vials with sodium polyanetholesulfonate than in vials without this agent. Vials with no blood inoculated with 265 CFU per vial showed turbidity 1 day before GVs became positive, proving that the major limiting detection factor was the low level of release of CO, and not an inadequate growth medium. In NR6 vials buffered to pH 6.2, GVs became positive faster and were higher than those in standard vials. NR6 vials at pH 6.2 with 0.3% sodium pyruvate yielded a positive GV in the first day of bacterial turbidity.
引用
收藏
页码:3200 / 3203
页数:4
相关论文
共 34 条
[1]  
Alton G. G. L. M., 1976, TECNICAS LABORATORIO
[2]  
ANHALT JP, 1978, DETECTION SEPTICEMIA, P109
[3]   EFFECT OF SODIUM POLYANETHOLESULFONATE ON ANTIMICROBIAL SYSTEMS IN BLOOD [J].
BELDING, ME ;
KLEBANOFF, SJ .
APPLIED MICROBIOLOGY, 1972, 24 (05) :691-698
[4]  
CHASE WM, 1968, METHODS IMMUNOLOGY I, V2, P398
[5]   COMPARATIVE-EVALUATION OF NONRADIOMETRIC BACTEC AND IMPROVED OXOID SIGNAL BLOOD CULTURE SYSTEMS IN A CLINICAL LABORATORY [J].
DALEY, C ;
LIM, I ;
MODRA, J ;
WILKINSON, I .
JOURNAL OF CLINICAL MICROBIOLOGY, 1990, 28 (07) :1586-1590
[6]  
DETEJADA GM, 1993, J BACTERIOL, V175, P5273
[7]  
Diaz R, 1989, BRUCELLOSIS CLIN LAB, P76
[8]   EFFECT OF SODIUM POLYANETHOL SULFONATE IN BLOOD CULTURES [J].
ENG, J .
JOURNAL OF CLINICAL MICROBIOLOGY, 1975, 1 (02) :119-123
[9]   THE METABOLISM OF BRUCELLAE - THE ROLE OF CELLULAR PERMEABILITY [J].
GERHARDT, P ;
MACGREGOR, DR ;
MARR, AG ;
OLSEN, CB ;
WILSON, JB .
JOURNAL OF BACTERIOLOGY, 1953, 65 (05) :581-586
[10]   SODIUM POLYANETHOL SULFONATE SENSITIVITY OF ANAEROBIC COCCI [J].
GRAVES, MH ;
MORELLO, JA ;
KOCKA, FE .
APPLIED MICROBIOLOGY, 1974, 27 (06) :1131-1133