PREPARATION OF FILTERS LOADED WITH WELDING DUST - A HOMOGENEITY AND STABILITY STUDY OF HEXAVALENT CHROMIUM

被引:29
作者
DYG, S [1 ]
ANGLOV, T [1 ]
CHRISTENSEN, JM [1 ]
机构
[1] NATL INST OCCUPAT HLTH,DEPT CHEM & BIOCHEM,DK-2100 COPENHAGEN,DENMARK
关键词
CHROMIUM SPECIATION; QUALITY CONTROL; STABILITY STUDIES;
D O I
10.1016/0003-2670(94)85073-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
One hundred filters were loaded with welding fume dust, collected in industrial working conditions, and the homogeneity and the stability of the materials with regard to Cr(VI) were verified. The filters were loaded, using a Sputnic air sampling unit containing 100 binderfree glass fibre filters. The filter load was determined by weighing before and after exposure. The mean amount of dust, charged on 98 filters amounted to 2.565 mg/filter (C.V. = 3.4%). The load of hexavalent chromium on the filters corresponds to loads usually found on occupationally charged filters (approx. Cr(VI) 100 mu g/filter). The homogeneity was verified by analyzing 16 filters selected from the four rings of the Sputnic air sampler. The results proved the homogeneity of Cr(VI) on the batch of filters. Filters were stored at 25 degrees C and -20 degrees C and the stability of Cr(VI) and total soluble Cr was verified after 1, 4 and 13 week(s). The results showed no significant difference between the filters stored at 25 degrees C and -20 degrees C. In all cases no Cr(III) could be detected (below LOD) with the analytical procedure used, and no significant difference was found between the amounts of Cr(VI) and total Cr determined. Normalization of the amount of hexavalent chromium measurements according to the dust Load substantially improves the analytical data.
引用
收藏
页码:273 / 282
页数:10
相关论文
共 46 条
[1]   OCCUPATIONAL CHRONIC EXPOSURE TO METALS .1. CHROMIUM EXPOSURE OF STAINLESS-STEEL WELDERS BIOLOGICAL MONITORING [J].
ANGERER, J ;
AMIN, W ;
HEINRICHRAMM, R ;
SZADKOWSKI, D ;
LEHNERT, G .
INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 1987, 59 (05) :503-512
[2]   DANISH EXTERNAL QUALITY ASSESSMENT SCHEME - AN INTERLABORATORY COMPARISON STUDY ON LEAD, CADMIUM AND CHROMIUM IN LYOPHILIZED HUMAN BLOOD CONCENTRATE [J].
ANGLOV, T ;
HOLST, E ;
CHRISTENSEN, JM .
INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 1993, 64 (06) :431-438
[3]  
ANGLOV T, 1992, FRESEN J ANAL CHEM, V345, P335
[4]  
[Anonymous], 1990, IARC MONOGRAPHS EVAL, V49
[5]  
BJORGO R, SPUTNIK AIR SAMPLING
[6]   CHROMIUM IN BIOLOGICAL SAMPLES FROM LOW-LEVEL EXPOSED STAINLESS-STEEL AND MILD-STEEL WELDERS [J].
BONDE, JP ;
CHRISTENSEN, JM .
ARCHIVES OF ENVIRONMENTAL HEALTH, 1991, 46 (04) :225-229
[7]   AN ANALYSIS OF LUNG-CANCER RISK FROM EXPOSURE TO HEXAVALENT CHROMIUM [J].
BRAVER, ER ;
INFANTE, P ;
CHU, K .
TERATOGENESIS CARCINOGENESIS AND MUTAGENESIS, 1985, 5 (05) :365-378
[8]  
CHRISTENSEN JM, 1993, SCI TOTAL ENVIRON, V132, P11
[9]   APPLICATION OF A NEW AMIQAS COMPUTER-PROGRAM FOR INTEGRATED QUALITY-CONTROL, METHOD EVALUATION AND PROFICIENCY TESTING [J].
CHRISTENSEN, SL ;
ANGLOV, JTB ;
CHRISTENSEN, JM ;
OLSEN, E ;
POULSEN, OM .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 345 (2-4) :343-350
[10]   USE OF REFERENCE MATERIALS IN TRACE-ELEMENT ANALYSIS OF FOODSTUFFS [J].
CORNELIS, R .
FOOD CHEMISTRY, 1992, 43 (04) :307-313