ANALYSIS OF EDDY CURRENTS IN NUCLEAR-MAGNETIC-RESONANCE IMAGING

被引:37
作者
AHN, CB [1 ]
CHO, ZH [1 ]
机构
[1] KOREA ADV INST SCI & TECHNOL,DEPT ELECT SCI,SEOUL 131,SOUTH KOREA
关键词
D O I
10.1002/mrm.1910170119
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The eddy currents in nuclear magnetic resonance (NMR) imaging are analyzed from the solutions of Maxwell's equations and their effects are examined over various experimental conditions from whole‐body diagnostic imaging to recently developed NMR microscopy. The analysis is focused mainly on the frequency characteristics and intensity variations of the eddy‐current‐induced field which depends on the overall system size, ratio of the gradient coil size to the magnet bore diameter, and the pulse‐sequence‐dependent parameters such as input current waveform and repetition time. From the analysis, the frequency response of the eddy‐current‐induced field is that of a high‐pass filter whose cutoff frequency is inversely proportional to the square of the overall system size. The intensity ratio of the generated field to the induced field is not affected by the overall system size, but is sensitively related to the ratio of the gradient coil size to the magnet bore diameter. © 1991 Academic Press, Inc. Copyright © 1991 Wiley‐Liss, Inc., A Wiley Company
引用
收藏
页码:149 / 163
页数:15
相关论文
共 17 条
  • [1] A GENERALIZED FORMULATION OF DIFFUSION EFFECTS IN MU-M RESOLUTION NUCLEAR MAGNETIC-RESONANCE IMAGING
    AHN, CB
    CHO, ZH
    [J]. MEDICAL PHYSICS, 1989, 16 (01) : 22 - 28
  • [2] THE EFFECTS OF RANDOM DIRECTIONAL DISTRIBUTED FLOW IN NUCLEAR-MAGNETIC-RESONANCE IMAGING
    AHN, CB
    LEE, SY
    NALCIOGLU, O
    CHO, ZH
    [J]. MEDICAL PHYSICS, 1987, 14 (01) : 43 - 48
  • [3] AN IMPROVED NUCLEAR-MAGNETIC-RESONANCE DIFFUSION-COEFFICIENT IMAGING METHOD USING AN OPTIMIZED PULSE SEQUENCE
    AHN, CB
    LEE, SY
    NALCIOGLU, O
    CHO, ZH
    [J]. MEDICAL PHYSICS, 1986, 13 (06) : 789 - 793
  • [4] AHN CB, IN PRESS IEEE T MED
  • [5] Bihan DL, 1988, RADIOLOGY, V168, P497
  • [6] NUCLEAR MAGNETIC-RESONANCE MICROSCOPY WITH 4-MU-M RESOLUTION - THEORETICAL-STUDY AND EXPERIMENTAL RESULTS
    CHO, ZH
    AHN, CB
    JUH, SC
    LEE, HK
    JACOBS, RE
    LEE, S
    YI, JH
    JO, JM
    [J]. MEDICAL PHYSICS, 1988, 15 (06) : 815 - 824
  • [7] CHO ZH, 1987, ENCY PHYSICAL SCI TE, V3, P533
  • [8] Jackson J.D., 1975, CLASSICAL ELECTRODYN, P206
  • [9] REDUCTION OF PULSED GRADIENT SETTLING TIME IN THE SUPERCONDUCTING MAGNET OF A MAGNETIC-RESONANCE INSTRUMENT
    JENSEN, DJ
    BREY, WW
    DELAYRE, JL
    NARAYANA, PA
    [J]. MEDICAL PHYSICS, 1987, 14 (05) : 859 - 862
  • [10] ACTIVE MAGNETIC SCREENING OF GRADIENT COILS IN NMR IMAGING
    MANSFIELD, P
    CHAPMAN, B
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1986, 66 (03) : 573 - 576