CONTRACTION RATES OF MESHED, NONEXPANDED SPLIT-THICKNESS SKIN-GRAFTS VERSUS SPLIT-THICKNESS SHEET GRAFTS

被引:12
作者
FIFER, TD [1 ]
PIEPER, D [1 ]
HAWTOF, D [1 ]
机构
[1] PROVIDENCE HOSP,SOUTHFIELD,MI 48037
关键词
D O I
10.1097/00000637-199308000-00015
中图分类号
R61 [外科手术学];
学科分类号
摘要
Contraction rates of wounds covered by meshed, nonexpanded split-thickness skin grafts were compared with split-thickness sheet-grafted wounds in a porcine model. No significant difference was found in wound contraction. When compared with previous studies, this study shows that differences in contraction previously observed were not a result of meshing and suggests that expansion may be the cause of the difference previously observed.
引用
收藏
页码:162 / 163
页数:2
相关论文
共 6 条
[1]
Corps B V, 1969, Br J Plast Surg, V22, P125, DOI 10.1016/S0007-1226(69)80053-6
[2]
KLEIN I, 1972, SURG GYNECOL OBSTET, V135, P49
[3]
CONTRACTION AND GROWTH OF WOUNDS COVERED BY MESHED AND NON-MESHED SPLIT THICKNESS SKIN-GRAFTS [J].
PETRY, JJ ;
WORTHAM, KA .
BRITISH JOURNAL OF PLASTIC SURGERY, 1986, 39 (04) :478-482
[4]
RUDOLPH R, 1976, SURG GYNECOL OBSTET, V142, P49
[5]
RUDOLPH R, 1973, SURG GYNECOL OBSTET, V136, P641
[6]
TANNER J C Jr, 1964, Plast Reconstr Surg, V34, P287