THE IDLE INTRAVENOUS CATHETER

被引:71
作者
LEDERLE, FA
PARENTI, CM
BERSKOW, LC
ELLINGSON, KJ
机构
[1] Department of Medicine (111-0), Minneapolis Dept. Vet. Aff. Med. C., Minneapolis, MN 55417, One Veterans Drive
[2] Department of Medicine (111), Minneapolis Dept. Vet. Aff. Med. C., Minneapolis, MN 55417, One Veterans Drive
[3] Pharmacy Service (119), Minneapolis Dept. Vet. Aff. Med. C., Minneapolis, MN 55417, One Veterans Drive
关键词
CATHETERIZATION; IATROGENIC DISEASE; CROSS INFECTION; BACTEREMIA; PHLEBITIS;
D O I
10.7326/0003-4819-116-9-737
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
. Objective: To assess the prevalence of idle peripheral intravenous (IV) catheters (those without any therapeutic use) on regular-care medical wards. . Design: Observation, interviews, and chart review. . Setting: A university-affiliated VA medical center. . Patients: All 959 inpatients on 4 regular-care medical wards during a 6-week period, including 484 IV catheter episodes and 2983 patient-days of IV catheter use. . Main Outcome Measure: Idle IV catheter use. . Results: Thirty-five percent of all IV catheter episodes (95% Cl, 32% to 38%) had 2 or more consecutive idle days. In only 6 of these (1%) could a specific reason for the catheter be determined. Seventeen percent of all patients on regular-care medical wards (Cl, 15% to 19%) had an idle IV catheter for 2 or more consecutive days. Twenty percent of all patient-days of IV catheter use were idle (Cl, 19% to 21%). . Conclusions: Our data suggest that IV are frequently used unnecessarily. Future efforts to reduce IV catheter complication rates should focus on reducing unnecessary use as well as on improving techniques to reduce infection rates when use is appropriate.
引用
收藏
页码:737 / 738
页数:2
相关论文
共 13 条
[1]   SYSTEMIC SEPSIS AND INTRAVENOUS DEVICES - A PROSPECTIVE SURVEY [J].
COLLIGNON, PJ ;
MUNRO, R ;
SORRELL, TC .
MEDICAL JOURNAL OF AUSTRALIA, 1984, 141 (06) :345-348
[2]  
GOLDMANN DA, 1973, ANN INTERN MED, V79, P848, DOI 10.7326/0003-4819-79-6-848
[3]   RATES OF NEEDLE-STICK INJURY CAUSED BY VARIOUS DEVICES IN A UNIVERSITY HOSPITAL [J].
JAGGER, J ;
HUNT, EH ;
BRANDELNAGGAR, J ;
PEARSON, RD .
NEW ENGLAND JOURNAL OF MEDICINE, 1988, 319 (05) :284-288
[4]   GAUZE VS PLASTIC FOR PERIPHERAL INTRAVENOUS DRESSINGS - TESTING A NEW TECHNOLOGY [J].
LITTENBERG, B ;
THOMPSON, L .
JOURNAL OF GENERAL INTERNAL MEDICINE, 1987, 2 (06) :411-414
[5]   RISK-FACTORS FOR INFUSION-RELATED PHLEBITIS WITH SMALL PERIPHERAL VENOUS CATHETERS - A RANDOMIZED CONTROLLED TRIAL [J].
MAKI, DG ;
RINGER, M .
ANNALS OF INTERNAL MEDICINE, 1991, 114 (10) :845-854
[6]   A COMPARATIVE-STUDY OF POLYANTIBIOTIC AND IODOPHOR OINTMENTS IN PREVENTION OF VASCULAR CATHETER-RELATED INFECTION [J].
MAKI, DG ;
BAND, JD .
AMERICAN JOURNAL OF MEDICINE, 1981, 70 (03) :739-744
[7]   EVALUATION OF DRESSING REGIMENS FOR PREVENTION OF INFECTION WITH PERIPHERAL INTRAVENOUS CATHETERS - GAUZE, A TRANSPARENT POLYURETHANE DRESSING, AND AN IODOPHOR-TRANSPARENT DRESSING [J].
MAKI, DG ;
RINGER, M .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1987, 258 (17) :2396-2403
[8]   EVIDENCE FOR AN INFORMAL CLINICAL POLICY RESULTING IN HIGH USE OF A VERY-LOW-YIELD TEST [J].
RICH, EC ;
CROWSON, TW ;
CONNELLY, DP .
AMERICAN JOURNAL OF MEDICINE, 1985, 79 (05) :577-582
[9]   GUIDELINES FOR PREVENTION OF INTRAVASCULAR INFECTIONS [J].
SIMMONS, BP .
INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 1982, 3 (01) :61-72
[10]  
TAGER IB, 1983, AM J EPIDEMIOL, V118, P839