THE 4-ELECTRODE RESISTIVITY TECHNIQUE IN ANISOTROPIC MEDIA - THEORETICAL-ANALYSIS AND APPLICATION ON MYOCARDIAL TISSUE IN-VIVO

被引:88
作者
STEENDIJK, P [1 ]
MUR, G [1 ]
VANDERVELDE, ET [1 ]
BAAN, J [1 ]
机构
[1] DELFT UNIV TECHNOL,FAC ELECT ENGN,DEPT ELECT ENGN,ELECTROMAGNET RES LAB,DELFT,NETHERLANDS
关键词
D O I
10.1109/10.245632
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Several aspects of the four-electrode resistivity technique were studied with special emphasis on the theoretical determination of penetration depth and sample volume in anisotropic media such as (cardiac) muscle. Moreover, the presence of a thin disturbing layer on top of the medium under study was analyzed. A four-electrode sensor was developed for the measurement of local myocardial resistivity in two orthogonal directions. The sensor was applied to the epicardium of anesthetized open chest dogs and, as an example, results are given on the frequency dependence (5-60 kHz) and the changes during the cardiac cycle of longitudinal and transverse myocardial resistivity.
引用
收藏
页码:1138 / 1148
页数:11
相关论文
共 32 条
[1]  
ACKMANN JJ, 1984, CRIT REV BIOMED ENG, V11, P281
[2]   CONTINUOUS MEASUREMENT OF LEFT-VENTRICULAR VOLUME IN ANIMALS AND HUMANS BY CONDUCTANCE CATHETER [J].
BAAN, J ;
VANDERVELDE, ET ;
DEBRUIN, HG ;
SMEENK, GJ ;
KOOPS, J ;
VANDIJK, AD ;
TEMMERMAN, D ;
SENDEN, J ;
BUIS, B .
CIRCULATION, 1984, 70 (05) :812-823
[3]   DIRECTIONAL DIFFERENCES OF IMPULSE SPREAD IN TRABECULAR MUSCLE FROM MAMMALIAN HEART [J].
CLERC, L .
JOURNAL OF PHYSIOLOGY-LONDON, 1976, 255 (02) :335-346
[4]   THE POTENTIAL DISTRIBUTION IN A LAYERED ANISOTROPIC SPHEROIDAL VOLUME CONDUCTOR [J].
DEMUNCK, JC .
JOURNAL OF APPLIED PHYSICS, 1988, 64 (02) :464-470
[5]  
FERRIS CD, 1974, INTRO BIOELECTRODES
[6]   RATE-DEPENDENT EFFECTS OF HYPOXIA ON INTERNAL LONGITUDINAL RESISTANCE IN GUINEA-PIG PAPILLARY-MUSCLES [J].
HIRAMATSU, Y ;
BUCHANAN, JW ;
KNISLEY, SB ;
GETTES, LS .
CIRCULATION RESEARCH, 1988, 63 (05) :923-929
[7]   The electrical conductivity of the tissues near the heart and its bearing on the distribution of the cardiac action currents [J].
Kaufman, W ;
Johnston, FD .
AMERICAN HEART JOURNAL, 1943, 26 (01) :42-54
[8]   ELECTRICAL UNCOUPLING AND INCREASE OF EXTRACELLULAR RESISTANCE AFTER INDUCTION OF ISCHEMIA IN ISOLATED, ARTERIALLY PERFUSED RABBIT PAPILLARY-MUSCLE [J].
KLEBER, AG ;
RIEGGER, CB ;
JANSE, MJ .
CIRCULATION RESEARCH, 1987, 61 (02) :271-279
[9]   SIMULATION STUDIES OF ELECTROCARDIOGRAM .1. NORMAL HEART [J].
MILLER, WT ;
GESELOWITZ, DB .
CIRCULATION RESEARCH, 1978, 43 (02) :301-315
[10]   COMPUTATION OF THE INPUT IMPEDANCES OF A CATHETER FOR CARDIAC VOLUMETRY [J].
MUR, G ;
BAAN, J .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1984, 31 (06) :448-453