EVALUATION OF THE SIGMA-60 APPLICATOR FOR REGIONAL HYPERTHERMIA IN TERMS OF SCATTERING PARAMETERS

被引:19
作者
LEYBOVICH, LB
MYERSON, RJ
EMAMI, B
STRAUBE, WL
机构
[1] WASHINGTON UNIV,SCH MED,EDWARD MALLINCKRODT INST RADIOL,CTR RADIAT ONCOL,ST LOUIS,MO 63110
[2] EDWARD HINES VET ADM MED CTR,DEPT RADIOL,HINES,IL 60141
关键词
D O I
10.3109/02656739109056459
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Scattering parameters adequately describe the interference between ports of a multiportal electromagnetic device when the device dimensions are comparable with the wavelength of the electromagnetic waves within the device. Since the Sigma 60 applicator is a four-port electromagnetic device, the interference between ports (quadrants) is described by a 4 x 4 scattering matrix. The load and frequency dependence of the scattering parameters were studied. The exact values of the parameters depends on the load within the applicator, but typically have minima at frequencies around 80 MHz and sometimes at 100-110 MHz. The effects of the coupling between quadrants can be substantial. Marked changes in the heating pattern can occur, particularly if the phase of the coupling element and the phase between quadrants both approach 90-degrees. Examples are shown in which the effects of coupling can qualitatively alter the intended SAR pattern. Simple steps which can be taken to minimize this phenomenon are demonstrated. Recommendations for clinical practice are discussed. Scattering parameters obtained with a non-absorbing phantom can be used for the quality assurance evaluation of the device.
引用
收藏
页码:917 / 935
页数:19
相关论文
共 12 条
[1]   CDRH RF PHANTOM FOR HYPERTHERMIA SYSTEMS EVALUATIONS [J].
ALLEN, S ;
KANTOR, G ;
BASSEN, H ;
RUGGERA, P .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1988, 4 (01) :17-23
[2]  
GUY AW, 1971, IEEE T MICROWAVE THE, V19, P224
[3]   STANFORD-UNIVERSITY INSTITUTIONAL REPORT .1. EVALUATION OF EQUIPMENT FOR HYPERTHERMIA TREATMENT OF CANCER [J].
KAPP, DS ;
FESSENDEN, P ;
SAMULSKI, TV ;
BAGSHAW, MA ;
COX, RS ;
LEE, ER ;
LOHRBACH, AW ;
MEYER, JL ;
PRIONAS, SD .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1988, 4 (01) :75-115
[4]   TUMOR-CONTROL IN LONG-TERM SURVIVORS FOLLOWING SUPERFICIAL HYPERTHERMIA [J].
MYERSON, RJ ;
PEREZ, CA ;
EMAMI, B ;
STRAUBE, W ;
KUSKE, RR ;
LEYBOVICH, L ;
VONGERICHTEN, D .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 18 (05) :1123-1129
[5]   PHYSICAL PREDICTORS OF ADEQUATE HYPERTHERMIA WITH THE ANNULAR PHASED-ARRAY [J].
MYERSON, RJ ;
EMAMI, BN ;
PILEPICH, MV ;
FIELDS, JN ;
PEREZ, CA ;
VONGERICHTEN, D ;
STRAUBE, W ;
NUSSBAUM, G ;
LEYBOVICH, L ;
SATHIASEELAN, V .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1989, 5 (06) :749-755
[6]   REGIONAL HYPERTHERMIA - A FEASIBILITY ANALYSIS [J].
PILEPICH, MV ;
MYERSON, RJ ;
EMAMI, BN ;
PEREZ, CA ;
LEYBOVICH, L ;
VONGERICHTEN, D .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1987, 3 (04) :347-351
[7]   HEATING DEEP SEATED ECCENTRICALLY LOCATED TUMORS WITH AN ANNULAR PHASED-ARRAY SYSTEM - A COMPARATIVE CLINICAL-STUDY USING 2 ANNULAR ARRAY OPERATING CONFIGURATIONS [J].
SAMULSKI, TV ;
KAPP, DS ;
FESSENDEN, P ;
LOHRBACH, A .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1987, 13 (01) :83-94
[8]   EVALUATION OF HYPERTHERMIA EQUIPMENT - UNIVERSITY-OF-UTAH INSTITUTIONAL REPORT .1. [J].
SAPOZINK, MD ;
GIBBS, FA ;
GIBBS, P ;
STEWART, JR .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1988, 4 (01) :117-132
[9]   THEORETICAL-ANALYSIS AND CLINICAL DEMONSTRATION OF THE EFFECT OF POWER PATTERN CONTROL USING THE ANNULAR PHASED-ARRAY HYPERTHERMIA SYSTEM [J].
SATHIASEELAN, V ;
ISKANDER, MF ;
HOWARD, GCW ;
BLEEHEN, NM .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1986, 34 (05) :514-519
[10]  
Stutzman WL, 1981, ANTENNA THEORY DESIG