EFFECT OF FEMORAL-HEAD SIZE ON WEAR OF THE POLYETHYLENE ACETABULAR COMPONENT

被引:808
作者
LIVERMORE, J [1 ]
ILSTRUP, D [1 ]
MORREY, B [1 ]
机构
[1] MAYO CLIN & MAYO FDN, BIOSTAT SECT, ROCHESTER, MN 55905 USA
关键词
D O I
10.2106/00004623-199072040-00008
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
A technique was developed to determine the wear of the acetabular component of a total hip replacement by examination of standardized initial and follow-up radiographs. Three hundred and eighty-five hips were followed for at least 9.5 years after replacement. The least amount and rate of linear wear were associated with use of a femoral head that had a diameter of twenty-eight millimeters (p < 0.001). The greatest amount and men rate of linear wear occurred with twenty-two-millimeter components, but these differences were not statistically significant. The greatest volumetric wear and mean rate of volumetric wear were seen with thirty-two-millimeter components (p < 0.001). A wider radiolucent line in acetabular Zone 1 was associated with use of the thirty-two-millimeter head. The amounts of resorption of the proximal part of the femoral neck and of lysis of the proximal part of the femur both correlated positively with the extent of linear and volumetric wear; this suggests an association between the amount of debris from wear and these changes in the femoral neck and proximal part of the femur.
引用
收藏
页码:518 / 528
页数:11
相关论文
共 81 条
[1]   MATERIALS FOR INTERNAL PROSTHESES - THE PRESENT POSITION AND POSSIBLE FUTURE-DEVELOPMENTS [J].
ATKINSON, JR ;
DOWLING, JM ;
CICEK, RZ .
BIOMATERIALS, 1980, 1 (02) :89-96
[2]   GRANULOMATOSIS OF BONE FROM HIGH-DENSITY POLYETHYLENE [J].
AUSTIN, RT ;
STONEY, PJ .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1982, 13 (05) :414-418
[3]   THE EFFECT OF CONFORMITY, THICKNESS, AND MATERIAL ON STRESSES IN ULTRAHIGH MOLECULAR-WEIGHT COMPONENTS FOR TOTAL JOINT REPLACEMENT [J].
BARTEL, DL ;
BICKNELL, VL ;
WRIGHT, TM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1986, 68A (07) :1041-1051
[4]   TOTAL HIP ARTHROPLASTY - REVIEW OF 333 CASES WITH LONG FOLLOW-UP [J].
BECKENBAUGH, RD ;
ILSTRUP, DM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1978, 60 (03) :306-313
[5]   CASE REPORT-246 - OSTEOLYSIS OF THE ILIUM ASSOCIATED WITH A LOOSE ACETABULAR CUP FOLLOWING TOTAL HIP-ARTHROPLASTY, SECONDARY TO FOREIGN-BODY REACTION TO POLYETHYLENE AND METHYL-METHACRYLATE [J].
BELL, RS ;
HAERI, GB ;
GOODMAN, SB ;
FORNASIER, VL .
SKELETAL RADIOLOGY, 1983, 10 (03) :201-204
[6]   WEAR BEHAVIOR OF MEDICAL ENGINEERING MATERIALS [J].
BEUTLER, H ;
LEHMANN, M ;
STAHLI, G .
WEAR, 1975, 33 (02) :337-350
[7]  
BEUTLER H, 1978, J BONE JOINT SURG BR, V60, P303
[8]   OSTEOLYTIC CHANGES IN THE UPPER FEMORAL-SHAFT FOLLOWING POROUS-COATED HIP-REPLACEMENT [J].
BROWN, IW ;
RING, PA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1985, 67 (02) :218-221
[9]  
BULLOUGH PG, 1973, HIP, P80
[10]  
CHAO EYS, 1973, P ANN C ENG MED BIOL, V15, P152