MICROSURGICAL 2-LAYER VASOVASOSTOMY - SIMPLIFIED TECHNIQUE USING HINGED, FOLDING-APPROXIMATING CLAMP

被引:6
作者
BELKER, AM [1 ]
机构
[1] UNIV LOUISVILLE,SCH MED,DEPT SURG,UROL SECT,LOUISVILLE,KY 40208
关键词
D O I
10.1016/0090-4295(80)90142-9
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:376 / 381
页数:6
相关论文
共 8 条
[1]  
BELKER A M, 1978, Urology, V11, P616, DOI 10.1016/0090-4295(78)90015-8
[2]  
BELKER AM, 1978, FERTIL STERIL, V29, P48
[3]   UROLOGIC MICRO-SURGERY - CURRENT PERSPECTIVES .1. VASOVASOSTOMY [J].
BELKER, AM .
UROLOGY, 1979, 14 (04) :325-329
[4]   MICROSURGICAL VASOVASOSTOMY - RELIABLE VASECTOMY REVERSAL [J].
OWEN, ER .
AUSTRALIAN AND NEW ZEALAND JOURNAL OF SURGERY, 1977, 47 (03) :305-309
[5]  
SHARLIP ID, 1979, FEB ANN M AM FERT SO
[6]  
Silber S J, 1975, Urology, V6, P150, DOI 10.1016/0090-4295(75)90701-3
[7]  
SILBER SJ, 1978, FERTIL STERIL, V29, P125
[8]   FOLDING-APPROXIMATING CLAMP TO SIMPLIFY MICROVASOVASOTOMY [J].
STRAUCH, B .
UROLOGY, 1980, 16 (03) :295-296