HEAT-PUMP ASSISTED CONTINUOUS DRYING .1. SIMULATION-MODEL

被引:34
作者
JOLLY, P
JIA, XG
CLEMENTS, S
机构
[1] Energy Laboratory, Department of Mechanical Engineering, University of Queensland
关键词
Continuous drying; Heat pump; Heat pump dehumidifier; Heat pump drying; Heat pump model;
D O I
10.1002/er.4440140707
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The addition of a heat pump to a conventional hot air drying system can enhance the efficiency of drying. To investigate the performance of heat pump assisted continuous drying system a detailed simulation model has been developed. The system modelled consists of a vapour compression heat pump coupled to a continuous cross‐flow dryer. The model takes account of detailed heat and mass transfer phenomena taking place in each component of the system and can be used to investigate many different system configurations. Copyright © 1990 John Wiley & Sons, Ltd
引用
收藏
页码:757 / 770
页数:14
相关论文
共 21 条
[1]  
(1981)
[2]  
Baines P.G., (1986)
[3]  
Baines P.G., Carrington C.G., Analysis of Rankine cycle heat pump dryers, Int. J. Energy Res., 12, pp. 495-510, (1988)
[4]  
Carrington C.G., Baines P.G., Second law limits in convective heat pump dryers, Int. J. Energy Res., 12, pp. 481-494, (1988)
[5]  
Conte S.D., Boor C.D., Elementary numerical analysis: an algorithmic approach, (1972)
[6]  
Domanski P., Didion D.A., Computer modelling of the vapor compression cycle with constant flow area expansion device, (1983)
[7]  
Geeraert B., Air drying by heat pumps with special reference to timber drying, Heat pumps and their contribution to energy conservation, pp. 219-246, (1976)
[8]  
Fischer S.K., Rice C.K., The Oak Ridge heat pump models: 1. A steady‐state computer design model for air‐to‐air heat pumps, (1983)
[9]  
Hodgett B., Efficient drying using heat pumps, Chemical Engineer, 311, pp. 510-512, (1976)
[10]  
Kartsounes G.T., Erth R.A., Computer calculation of the thermodynamic properties of refrigerants 12, 22 and 502, ASHRAE Trans., 77, 2, (1971)