THE DEPENDENCE OF THE SCATTERED RADIATION-DOSE TO PERSONNEL ON TECHNIQUE FACTORS IN DIAGNOSTIC-RADIOLOGY

被引:53
作者
MARSHALL, NW
FAULKNER, K
机构
[1] Medical Physics Department, Newcastle General Hospital, Newcastle-Upon-Tyne NE4 6BE, Westgate Road
关键词
RADIOLOGY; RADIATION PROTECTION;
D O I
10.1259/0007-1285-65-769-44
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The measurement and prediction of scattered radiation dose to staff in diagnostic radiology is particularly important, owing to the increased use and complexity of interventional radiology. The air kerma-area product and scattered radiation dose in the vicinity of the patient couch, for both overcouch and undercouch X-ray tube geometries, were simultaneously monitored. The scattered radiation distribution at the couchside was deduced at a range of tube potentials for both overcouch and undercouch X-ray tube geometries. The variation of scattered radiation with field size on both geometries was investigated, as well as the variation with focus-table distance on an overcouch tube geometry. It was discovered that the scattered radiation dose at a point correlated with the air kerma-area product and the result may be used for radiation protection purposes. A method of predicting the scattered radiation dose at a given position is described.
引用
收藏
页码:44 / 49
页数:6
相关论文
共 8 条
[1]   AN ASSESSMENT OF THE RADIATION-DOSE RECEIVED BY STAFF USING FLUOROSCOPIC EQUIPMENT [J].
FAULKNER, K ;
MOORES, BM .
BRITISH JOURNAL OF RADIOLOGY, 1982, 55 (652) :272-276
[2]   RADIATION PROTECTION IN FLUOROSCOPY WITH AN IMAGE INTENSIFIER [J].
HEMMINGSSON, A ;
LOFROTH, PO .
ACTA RADIOLOGICA-DIAGNOSIS, 1978, 19 (06) :1007-1013
[3]  
Her Majesty's Stationery Office, 1985, IONISING RAD REGULAT
[4]  
HOFFMANN JR, 1971, RADIOLOGY, V97, P551
[5]   AN INVESTIGATION OF THE RADIATION-DOSE TO STAFF DURING CARDIAC RADIOLOGICAL STUDIES [J].
JEANS, SP ;
FAULKNER, K ;
LOVE, HG ;
BARDSLEY, RA .
BRITISH JOURNAL OF RADIOLOGY, 1985, 58 (689) :419-428
[6]   DOSES TO HEAD AND ARMS OF RADIOLOGISTS DURING FLUOROSCOPY [J].
LAW, J .
BRITISH JOURNAL OF RADIOLOGY, 1985, 58 (686) :187-188
[7]   EYE DOSE LIMITS AND THE USE OF OVERCOUCH AND UNDERCOUCH X-RAY IMAGE INTENSIFIER SYSTEMS [J].
PALMER, KE ;
WRIGHT, IH .
BRITISH JOURNAL OF RADIOLOGY, 1985, 58 (696) :1221-1223
[8]   PERSONNEL PROTECTION DURING CARDIAC-CATHETERIZATION WITH A COMPARISON OF HAZARDS OF UNDERCOUCH AND OVERCOUCH X-RAY TUBE MOUNTINGS [J].
STACEY, AJ ;
DAVIS, R ;
KERR, IH .
BRITISH JOURNAL OF RADIOLOGY, 1974, 47 (553) :16-23