CONTRAST-ENHANCED TRANSCRANIAL DOPPLER US WITH A NEW TRANSPULMONARY ECHO CONTRAST AGENT BASED ON SACCHARIDE MICROPARTICLES

被引:54
作者
ROSENKRANZ, K
ZENDEL, W
LANGER, R
HEIM, T
SCHUBEUS, P
SCHOLZ, A
SCHLIEF, R
SCHURMANN, R
FELIX, R
机构
[1] Department of Radiology, Rudolf Virchow University Clinics, Freie Universitat Berlin, Berlin
关键词
BRAIN; BLOOD FLOW; US; GALACTOSE; ULTRASOUND; (US); CONTRAST MEDIA;
D O I
10.1148/radiology.187.2.8475287
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this first patient study (phase II) was to evaluate the clinical usefulness of a new echo contrast agent at transcranial Doppler ultrasonography (US). Twenty patients were selected from a group of 242 patients undergoing conventional transcranial Doppler US who had low (n = 18) or absent (n = 2) Doppler signals from the middle cerebral artery (MCA). The extent and duration of Doppler signal increase was measured in 30 MCAs and in 14 basilar arteries following the intravenous injection of a transpulmonary galactose microparticle suspension (SH U 508 A) at three concentrations (200, 300, and 400 mg/mL). Doppler waveform analysis became possible in 93% (28 of 30) of the MCAs following injection. The maximal increase in average Doppler signal intensity (11 dB at 200 mg/mL, 15 dB at 300 mg/mL, and 17 dB at 400 mg/mL) and the increase in average duration of the signal enhancement (163 seconds at 200 mg/mL, 219 seconds at 300 mg/mL, and 240 seconds at 400 mg/mL) depended on contrast agent concentration. Doppler waveform analysis became possible in 79% (11 of 14) of the basilar arteries. The intravenous injection of this new echo contrast agent markedly increases Doppler signal intensity in patients with nondiagnostic results at conventional Doppler US.
引用
收藏
页码:439 / 443
页数:5
相关论文
共 19 条
  • [1] NON-INVASIVE TRANSCRANIAL DOPPLER ULTRASOUND RECORDING OF FLOW VELOCITY IN BASAL CEREBRAL-ARTERIES
    AASLID, R
    MARKWALDER, TM
    NORNES, H
    [J]. JOURNAL OF NEUROSURGERY, 1982, 57 (06) : 769 - 774
  • [2] Aaslid R, 1986, TRANSCRANIAL DOPPLER, P39
  • [3] TRANSCRANIAL DOPPLER SONOGRAPHY - EXAMINATION TECHNIQUE AND NORMAL REFERENCE VALUES
    ARNOLDS, BJ
    VONREUTERN, GM
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1986, 12 (02) : 115 - 123
  • [4] BECHER H, 1988, Z KARDIOL, V77, P227
  • [5] IMPROVED SENSITIVITY OF COLOR DOPPLER BY SH-U-454
    BECHER, H
    SCHLIEF, R
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1989, 64 (05) : 374 - 377
  • [6] BIBRA H V, 1989, Zeitschrift fuer Kardiologie, V78, P101
  • [7] IDENTIFICATION OF THE BASILAR ARTERY BY TRANSCRANIAL DOPPLER SONOGRAPHY
    BUDINGEN, HJ
    STAUDACHER, T
    [J]. ULTRASCHALL IN DER MEDIZIN, 1987, 8 (02): : 95 - 101
  • [8] SAFETY AND EFFICACY OF A NEW TRANSPULMONARY ULTRASOUND CONTRAST AGENT - INITIAL MULTICENTER CLINICAL-RESULTS
    FEINSTEIN, SB
    CHEIRIF, J
    TENCATE, FJ
    SILVERMAN, PR
    HEIDENREICH, PA
    DICK, C
    DESIR, RM
    ARMSTRONG, WF
    QUINONES, MA
    SHAH, PM
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (02) : 316 - 324
  • [9] DEMONSTRATION OF TUBAL PATENCY WITH COLOR-CODED DUPLEX SONOGRAPHY COMBINED WITH AN ULTRASONIC CONTRAST-MEDIUM
    FOBBE, F
    BECKER, R
    KOCH, HC
    HAMMERSTEIN, J
    WOLF, KJ
    [J]. FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1991, 154 (04): : 349 - 353
  • [10] ARTERIAL ASSESSMENT BY DOPPLER-SHIFT ULTRASOUND
    GOSLING, RG
    KING, DH
    [J]. PROCEEDINGS OF THE ROYAL SOCIETY OF MEDICINE-LONDON, 1974, 67 (06): : 447 - 449