AUTOLOGOUS BLOOD-TRANSFUSION IN REVISION HIP-ARTHROPLASTY - A PROSPECTIVE, CONTROLLED-STUDY OF 30 PATIENTS

被引:12
作者
ELAWAD, AAR
OHLIN, AK
BERNTORP, E
NILSSON, IM
FREDIN, H
机构
[1] UNIV LUND HOSP,DEPT CLIN CHEM,S-22185 LUND,SWEDEN
[2] MALMO GEN HOSP,DEPT COAGULAT DISORDERS,S-21401 MALMO,SWEDEN
来源
ACTA ORTHOPAEDICA SCANDINAVICA | 1992年 / 63卷 / 04期
关键词
D O I
10.3109/17453679209154747
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
In a prospective, randomized study of the efficacy and effects of autologous blood transfusion in revision hip arthroplasty, 30 patients were randomly allocated into two groups. The Control Group received homologous blood transfusion. The Study Group deposited 2-3 units of blood preoperatively, intraoperative blood salvage was used, and no homologous blood was transfused intraoperatively. There was a smaller postoperative blood loss in the Study Group. The preoperative hemoglobin values were lower in the Study Group, but one week postoperatively they were higher than in the Control Group. The decrease in the values of AT III and protein C was lower in the Study Group. The combination of preoperative blood donation and intraoperative blood salvage reduced blood loss and homologous blood transfusion in revision hip arthroplasty.
引用
收藏
页码:373 / 376
页数:4
相关论文
共 9 条
[1]  
BRENER BJ, 1973, ARCH SURG-CHICAGO, V107, P78
[2]   PREDONATION AUTOLOGOUS BLOOD IN HIP-ARTHROPLASTY [J].
ELAWAD, AAR ;
JONSSON, S ;
LAURELL, M ;
FREDIN, H .
ACTA ORTHOPAEDICA SCANDINAVICA, 1991, 62 (03) :218-222
[3]   INTRAOPERATIVE AUTOTRANSFUSION IN PRIMARY HIP-ARTHROPLASTY - A RANDOMIZED COMPARISON WITH HOMOLOGOUS BLOOD [J].
ELAWAD, AAR ;
OHLIN, AK ;
BERNTORP, E ;
NILSSON, IM ;
FREDIN, H .
ACTA ORTHOPAEDICA SCANDINAVICA, 1991, 62 (06) :557-562
[4]  
FRIBERGER P, 1983, SEMIN THROMB HEMOST, V9, P281
[5]   THE HOSPITAL TRANSFUSION COMMITTEE - GUIDELINES FOR IMPROVING PRACTICE [J].
GRINDON, AJ ;
TOMASULO, PS ;
BERGIN, JJ ;
KLEIN, HG ;
MILLER, JD ;
MINTZ, PD ;
TOMASULO, PA .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1985, 253 (04) :540-543
[6]  
LAW KJ, 1989, CLIN ORTHOP RELAT R, V245, P145
[7]   CHANGES IN THE PLASMA-LEVELS OF VITAMIN-K-DEPENDENT PROTEIN-C AND PROTEIN-S AND OF C4B-BINDING PROTEIN DURING PREGNANCY AND ORAL CONTRACEPTION [J].
MALM, J ;
LAURELL, M ;
DAHLBACK, B .
BRITISH JOURNAL OF HAEMATOLOGY, 1988, 68 (04) :437-443
[8]  
Nilsson IM, 1974, HAEMORRHAGIC THROMBO
[9]   INTRAOPERATIVE AUTOLOGOUS TRANSFUSION IN REVISION TOTAL HIP-ARTHROPLASTY [J].
WILSON, WJ .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1989, 71A (01) :8-14