A COMPARISON OF THE DETECTION SENSITIVITY OF LYMPHOCYTE MEMBRANE-ANTIGENS USING FLUORESCEIN AND PHOSPHOR IMMUNOCONJUGATES

被引:7
作者
BEVERLOO, HB [1 ]
VANSCHADEWIJK, A [1 ]
ZIJLMANS, HJ [1 ]
VERWOERD, NP [1 ]
BONNETT, J [1 ]
VROLIJK, H [1 ]
TANKE, HJ [1 ]
机构
[1] LEIDEN UNIV, SYLVIUS LAB, DEPT CYTOCHEM & CYTOMETRY, WASSENAARSEWEG 72, 2333 AL LEIDEN, NETHERLANDS
关键词
SENSITIVITY; FLUORESCENCE; LUMINESCENCE; IMMUNOPHOSPHORS; TIME-RESOLVED FLUORESCENCE MICROSCOPY; IMMUNOCYTOCHEMICAL STAINING;
D O I
10.1177/41.5.8468453
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
In this study we compared the sensitivity of immunocytochemical procedures, using conventional and time-resolved fluorescent dyes, in a model system consisting of paraformaldehyde-fixed human lymphocytes. The lymphocytes were stained for the presence of the CD4 epitope by indirect immunofluorescence using FITC as label or by using time-resolved luminescent immunophosphors. These immunophosphors were primarily developed for use under time-resolved fluorescence conditions, but they are also very well suited for use in conventional fluorescence microscopes. The differently labeled cells were first examined visually with a conventional fluorescence microscope in a double-blind study. The fluorescence was also measured with a CCD camera mounted on a specially constructed time-resolved fluorescence microscope which allows the suppression of the fast decaying fluorescence, thereby permitting visualization of the specific, slowing decaying luminescence of the phosphor label. With this microscope FITC and immunophosphor labeled lymphocytes were compared under normal conditions (i.e., continuous excitation) and under conditions of time-resolved registration. Conventional fluorescence microscopy revealed a better sensitivity in favor of the phosphor conjugates. This difference became more prominent when the preparations were quantitatively assessed with the CCD-time-resolved microscope. Time-resolved microscopy permitted a suppression of fast decaying fluorescence better than 1 to 10(6).
引用
收藏
页码:719 / 725
页数:7
相关论文
共 17 条
[1]  
AIKENS RS, 1989, METHOD CELL BIOL, V29, P291
[2]   AUTOFLUORESCENCE OF VIABLE CULTURED MAMMALIAN-CELLS [J].
AUBIN, JE .
JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 1979, 27 (01) :36-43
[3]   IMMUNOCHEMICAL DETECTION OF PROTEINS AND NUCLEIC-ACIDS ON FILTERS USING SMALL LUMINESCENT INORGANIC CRYSTALS AS MARKERS [J].
BEVERLOO, HB ;
VANSCHADEWIJK, A ;
ZIJLMANS, HJMAA ;
TANKE, HJ .
ANALYTICAL BIOCHEMISTRY, 1992, 203 (02) :326-334
[4]   PREPARATION AND MICROSCOPIC VISUALIZATION OF MULTICOLOR LUMINESCENT IMMUNOPHOSPHORS [J].
BEVERLOO, HB ;
VANSCHADEWIJK, A ;
BONNET, J ;
VANDERGEEST, R ;
RUNIA, R ;
VERWOERD, NP ;
VROLIJK, J ;
PLOEM, JS ;
TANKE, HJ .
CYTOMETRY, 1992, 13 (06) :561-570
[5]   INORGANIC PHOSPHORS AS NEW LUMINESCENT LABELS FOR IMMUNOCYTOCHEMISTRY AND TIME-RESOLVED MICROSCOPY [J].
BEVERLOO, HB ;
VANSCHADEWIJK, A ;
VANGELDERENBOELE, S ;
TANKE, HJ .
CYTOMETRY, 1990, 11 (07) :784-792
[6]   3'-END FLUOROCHROMIZED AND HAPTENIZED OLIGONUCLEOTIDES AS INSITU HYBRIDIZATION PROBES FOR MULTIPLE, SIMULTANEOUS RNA DETECTION [J].
DIRKS, RW ;
VANGIJLSWIJK, RPM ;
VOOIJS, MA ;
SMIT, AB ;
BOGERD, J ;
VANMINNEN, J ;
RAAP, AK ;
VANDERPLOEG, M .
EXPERIMENTAL CELL RESEARCH, 1991, 194 (02) :310-315
[7]   CYANINE DYE LABELING REAGENTS FOR SULFHYDRYL-GROUPS [J].
ERNST, LA ;
GUPTA, RK ;
MUJUMDAR, RB ;
WAGGONER, AS .
CYTOMETRY, 1989, 10 (01) :3-10
[8]   THE USE OF A CHARGE-COUPLED DEVICE FOR QUANTITATIVE OPTICAL MICROSCOPY OF BIOLOGICAL STRUCTURES [J].
HIRAOKA, Y ;
SEDAT, JW ;
AGARD, DA .
SCIENCE, 1987, 238 (4823) :36-41
[9]   ISOLATION OF AUTO-FLUORESCENT AGED HUMAN-FIBROBLASTS BY FLOW SORTING - MORPHOLOGY, ENZYME-ACTIVITY AND PROLIFERATIVE CAPACITY [J].
JONGKIND, JF ;
VERKERK, A ;
VISSER, WJ ;
VANDONGEN, JM .
EXPERIMENTAL CELL RESEARCH, 1982, 138 (02) :409-417
[10]   LUMINESCENCE DIGITAL IMAGING MICROSCOPY [J].
JOVIN, TM ;
ARNDTJOVIN, DJ .
ANNUAL REVIEW OF BIOPHYSICS AND BIOPHYSICAL CHEMISTRY, 1989, 18 :271-308