NORMAL CENTRAL VENOUS PRESSURE, SIGNIFICANCE OF REFERENCE POINT AND NORMAL RANGE

被引:18
作者
DEBRUNNER, F
BUHLER, F
机构
[1] Department of Internal Medicine, University of Basle
来源
BMJ-BRITISH MEDICAL JOURNAL | 1969年 / 3卷 / 5663期
关键词
D O I
10.1136/bmj.3.5663.148
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The principal methods for determining the central venous pressure have been compared in 26 patients undergoing cardiac catheterization. The method in which the reference point is taken to be 10 cm above the surface supporting a horizontal patient gave false high-pressure values. All the other methods, however, gave pressure values which corresponded to those obtained in the catheter studies. © 1969, British Medical Journal Publishing Group. All rights reserved.
引用
收藏
页码:148 / +
页数:1
相关论文
共 13 条
[1]  
BURRI C, 1966, SCHWEIZ MED WSCHR, V96, P624
[2]  
BURRI C, 1967, SCHWEIZ MED WSCHR, V97, P1414
[3]  
Cournand A, 1943, SURGERY, V13, P964
[4]   A PHYSIOLOGIC REFERENCE POINT FOR MEASURING CIRCULATORY PRESSURES IN THE DOG - PARTICULARLY VENOUS PRESSURE [J].
GUYTON, AC ;
GREGANTI, FP .
AMERICAN JOURNAL OF PHYSIOLOGY, 1956, 185 (01) :137-141
[5]  
HARDAWAY RM, 1968, CLINICAL MANAGEMENT, P163
[6]   NORMAL CENTRAL VENOUS PRESSURE [J].
JAIKARAN, SM ;
SAGAY, E .
BRITISH JOURNAL OF SURGERY, 1968, 55 (08) :609-+
[7]   The measurement of venous pressure by the direct method [J].
Lyons, RH ;
Kennedy, JA ;
Burwell, CS .
AMERICAN HEART JOURNAL, 1938, 16 :675-693
[8]  
MENDEL D, 1968, PRACTICE CARDIAC CAT, P222
[9]  
Moritz F, 1910, DTSCH ARCH KLIN MED, V98, P475
[10]  
POPPE H, 1961, TECHNIK RONTGENDIAGN, P535