MODIFICATION OF METOCLOPRAMIDE GLC ASSAY - APPLICATION TO HUMAN BIOLOGICAL SPECIMENS
被引:19
作者:
TAM, YK
AXELSON, JE
ONGLEY, R
机构:
[1] UNIV BRITISH COLUMBIA,FAC PHARMACEUT SCI,VANCOUVER V6T 1W5,BC,CANADA
[2] UNIV BRITISH COLUMBIA,FAC MED,VANCOUVER V6T 1W5,BC,CANADA
关键词:
Antiemetic agents—metoclopramide;
electron‐capture GLC analysis;
human plasma and urine;
GLC;
electron capture—analysis;
metoclopramide;
Metoclopramide—analysis;
electron‐capture GLC;
D O I:
10.1002/jps.2600681015
中图分类号:
R914 [药物化学];
学科分类号:
100701 ;
摘要:
A modified electron‐capture GLC assay for metoclopramide in human biological specimens is reported. This assay involves the incorporation of a back‐extraction method to remove endogenous contaminants. Its applicability was demonstrated by studying the time course of metoclopramide in plasma and urine from a human subject. The lowest quantifiable metoclopramide concentration in plasma was 7 ng/ml, provided 0.5 ml of plasma was used. Copyright © 1979 Wiley‐Liss, Inc., A Wiley Company